469596
6
Zoom out
Zoom in
Previous page
1/12
Next page
6
3 Operation
Instructions for use VUI 362-76
Fig. 3.4: Checking the water level
3.3 Domestic hot water operation
Warning!
The boiler should only be used when the heating
system contains water. Use of the boiler without
water may cause damage to the boiler or its
components.
Setting the maximum domestic hot water
temperature control
Turn the main switch (2, Fig. 3.5) to the "l" position.
The domestic hot water temperature can be adjusted
using the hot water temperature control (3, Fig. 3.5).
Turn the control clockwise to increase the
temperature and anti-clockwise to decrease the
temperature.
As a guide for normal circumstances set the knob to the
one o´clock position.
Note!
This control adjusts the maximum domestic hot
water temperature. If adjusting the control
upwards appears to have no effect on the
temperature, then the boiler is already operating
at full output for the selected flow rate.
Warning!
If you live in a hard water area please do not set
the control knob above the mid (12 o'clock)
position to prevent excessive scale formation
(fig. 3.5).
VRC-VC
C
o
0
I
C
o
1
3.2 Initial checks before turning ON
3.2.1 Open the service valves
Ensure the cold water service valve is open. This can
be checked by opening a hot water tap and ensuring
water flows.
Ensure that the service valves in the heating flow and
return (2 and 1) and the gas service valve (3) are open.
Note!
The flow, return and gas service valves are open
when the line marking has the same direction as
the pipe.
The pressure relief valves (4) are provided for safety
reasons and must not be interfered with.
Note!
A bottom cover is fitted to the appliance. The
service valves can be seen through the cover.
Fig. 3.3: Opening service valves
3.2.2 Check the water contents
Check the water contents of the system on the
pressure gauge (1).
The needle on the pressure gauge (1) should be within
the green band (between 1 and 1.5 bar). If the needle
displays a value below 0.75 bar when the appliance is
cold, follow the instructions left by your installer to refill
the system. Alternatively, your installer should be called
to refill the system.
I
0
2 3 1 4
834641_12GB_032005.qxd 09.03.2005 16:42 Uhr Seite 6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vaillant aquaPLUS VUI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vaillant aquaPLUS VUI in the language / languages: English as an attachment in your email.

The manual is 0,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vaillant aquaPLUS VUI

Vaillant aquaPLUS VUI Installation Guide - English - 56 pages

Vaillant aquaPLUS VUI User Manual - English, German - 40 pages

Vaillant aquaPLUS VUI Manual - Dutch - 2 pages

Vaillant aquaPLUS VUI User Manual - Dutch, French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info