Installation of the control panels
When using control panels which are specific to the
vehicle or the manufacturer, the electrical connection
must be established in accordance with the Truma interface
descriptions (refer to Electrical connection 230 V). Any modi-
fication made to the Truma components pertaining to this
will lead to the invalidation of the guarantee, as well as to the
exclusion of any claims for liability. The installer (manufacturer)
is responsible for providing instructions for use for the user as
well as for identification printing on the control panels.
When selecting the location, please bear the length of the
connection cable
of 3 m. If required, a cable extension of 5 m
can be supplied (please refer to page 14).
66 mm
Ø 55 mm
30
29
28
25
33
33
32
32
26
31
31
27
28
27a
Ø 50 mm
If it is not possible to install the control panels flush
with the surface, Truma can provide a surface-mount-
ing frame (25) on request, as a special accessory (part no.
40000-52600).
The control panel for gas operation (26) and (if provided by
Truma) the control panel for electrical operation (27) should be
fitted next to one another if at all possible (distance between
centres of holes 66 mm).
In each case, drill a hole with diameter 55 mm (gas operation)
and 50 mm (electrical operation) – distance between centres
of holes 66 mm –.
Plug the control panel cable (28) to the control panel for gas
operation (26) and then fit on the rear cover cap (29) as a
stress-relieving device.
Connect the control panel with a cable (30) 4 x 1.5 mm² (not
in the scope of delivery – see “Connection 230 V control pan-
el”). Feed the cable through the back cover (27a) and secure
with the strain relief.
Push the cable through to the rear and lay the connection ca-
bles (28 + 30) to the water heater.
Lay the connection cable with the orange multipole connec-
tor (28) to the 12 V electronic control unit (for connection see
“Electrical connection 12 V”).
Secure both control panels with 4 screws (31) each.
On the 230 V control panel it must be ensured, that the
rear cover locks correctly and fixed between the instal-
lation wall and the control panel frame. The rear protection
cover must not be removable when the control panel is
mounted!
Push on the front cover frame (32).
To round off the appearance of the cover frame, Truma
can provide side pieces (33) as special accessories in
8 different colours (please ask your dealer).
Electrical connection 12 V
Always disconnect the appliance from the power supply prior
to working on electrical components. It is not sufficient to just
switch off at the control panel!
The appliance must be disconnected from the vehicle main
power supply when carrying out any electric welding work on
the vehicle body.
If the connections are transposed there is a risk of
cable burning. This also rules out any guarantee or
liability claims.
Unscrew cover (34) from the electronic control unit. Slide
cable connector of control panel (28a) onto the p.c.b..
Put the cable (28) into the cable guide (28b) to fasten it securely.
The electrical connection 12 V is made at terminal (35).
orange = positive 12 V
blue = negative
To connect press with a small screwdriver from above and
push in cable from the front.
Connect to fused vehicle mains (central electrical equipment
5 – 10 A) using a 2 x 1.5 mm² cable.
Negative cable to central earth. With lengths of over 6 m use
a cable 2 x 2.5 mm². If connecting directly to the battery, the
positive and negative cable must be fused. Screw cover (34)
back on.
If necessary remove the outer cable mantle around the lead-
through of the cover.
There are to be no other 12 V consuming appliances con-
nected to the supply line!
The water heater fuse (36), 1.6 A, (slow-acting) is on the
p.c.b..
28a
28b
28
35
34
36
When power packs or power supply units are being
used, note that the output voltage is between 11 V and
15 V and the alternating current ripple is < 1.2 Vpp. We rec-
ommend the automatic chargers from Truma for the different
applications. Please ask your dealer. Other chargers may be
used only with a 12 V battery as a buffer.
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Ultrastore Rapid GE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Ultrastore Rapid GE in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info