Fault Cause Rectification
Gas operation
When switching on, the
heater does not operate.
No 12 V supply voltage.
Window open.
Check the power supply (operation voltage min. 10.5 V).
Check the water heater fuse
(refer to mainanance “Fuses”).
Close any windows above the cowl.
When switching on, the heater
does not operate and the red
lamp lights up after approx.
30 secs.
Heater operates for a prolonged
time and then the red lamp
lights up.
Cowl cover fitted.
No gas supply.
Incorrect gas pressure.
Air in the gas supply.
Over temperature sensor
has responded.
Remove cowl cover and / or clear any obstruction.
Check gas valves and gas bottle.
Check gas valves and gas bottle.
To unlock (and purge air), switch off the appliance, wait
5 minutes, and switch on again.
Check water content, refill if required (close drain valve).
To unlock, switch off the appliance, wait 5 minutes, and
switch on again.
Electrical operation
When switching on, the
heater does not operate.
No 230 V supply voltage.
Over temperature sensor
has responded.
Too slow warm-up in
position 850 W.
Connect the caravan to the site supply and / or check
residual current circuit breaker.
Check water content, refill if required (close drain valve).
The electrical heating element is fitted with an excess
temperature cut-out. In event of a fault, switch off at the
control panel, wait 10 minutes, then switch on again.
Please contact the Truma Service.
Water supply
Water drips from the
safety/drain valve.
When opening the cold water
tap, hot water tap comes out.
Water pressure to high.
Hot water flows back
through the cold water
supply.
Check water pressure (max. 2.8 bar), use a pressure
reducer when connected to central water supply.
Fit a no-return valve in the cold water supply
(refer to installation instructions “Water connection”).
If this does not solve the problem, please contact the Truma Service.
Trouble-shooting list
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Ultrastore Rapid GE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Ultrastore Rapid GE in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info