Selecting the remote controller functions
Change the settings of the remote controller functions
as required by taking the steps below.
How to change the remote controller functions
1 While operation is shut down, push the button
(43) and button (48) together for at least 4
seconds.
The numeric displays and display blink,
and the fixed louvers display lights.
2 Push the TEMP and buttons (49).
Repeatedly push the buttons until the setting to be
changed blinks on the display.
3 Push the TIME and buttons (40).
Repeatedly push the buttons until the setting to be
changed blinks on the display.
4 Push the button (42). Then push the button
(43) to return to the original screen.
When the button (42) is pushed, the numeric
displays and display stop blinking and
light up, and when the button (43) is pushed
again, they go off.
Items to be set
24-hour/12-hour display setting <code No.10>
The 24-hour display or 12-hour (AM/PM) display
can be selected for the clock which is displayed on
the remote controller.
This item’s selection is also reflected on the clock
displayed on the clock setting screen and program
input screen.
Restriction on button operations <code No.12>
This item sets the range of the restriction placed on
the button operations which can be applied while
scheduled operations are being performed.
Setting: 0000 (factory setting)
Code No.12
O: Can be operated.
X: Cannot be operated.
Display/non-display of clock <code no.13>
This item selects and sets whether the day of the week
and clock time are to be displayed.
Setting: 0000 (factory setting)
Code No.13
O: Display X: No display
Selection of operation when power is restored after a
power outage <code No.14>
This item selects the operation to be performed when
power is restored after a power outage occurred
during a scheduled operation.
0000: No operations are performed when the power is
restored, and the scheduled operation is resumed as
soon as the program time is reached after the power
has been restored. (When the power is restored, the
scheduled operation is based on the operation of the
indoor units.)
0001: If there was a programmed operation during the
power outage, that operation is performed when the
program is resumed. If there is no programmed
operation or if the “Continue xx” setting is in place, the
operation prior to the power outage is resumed.
Selecting the functions using the DIP
switches of the remote controller
The following functions can be selected using the DIP
switches on the remote controller’s circuit board.
Setting procedure
Open the back cover of the remote controller, and
select the functions using the DIP switches located at
the bottom left of the circuit board.
After establishing the settings, turn the ground fault
interrupter off and then back on.
Setting items
Remote controller header/follower setting: Bit 1
When operating the air conditioner using two remote
controllers, set one of the controls to be the follower.
* Set the remote controller used as the schedule timer
to be the header.
Operation function setting: Bit 2
One of the following three operation functions can be
selected and set.
1.Scheduled operation function
2.Timer operation function
3.No scheduled or timer operation function
Setting Description
0000:
0001:
24-hour display (factory setting)
12-hour (AM/PM) display
Setting [ON/OFF] [MODE] [TEMP.]
0000 O O O
0001 X O X
0002 X X X
0003 O X X
0004 O X O
Setting
Scheduled operation
underway
Scheduled operation
in standby
Air
conditioner
now
operating
Air
conditioner
now shut
down
Air
conditioner
now
operating
Air
conditioner
now shut
down
0000 O O O O
0001 X X X X
0002 O O X X
0003 O X X X
0004 O O O X
0005 O X O X
20


Need help? Post your question in this forum.

Forumrules
1

Forum

toshiba-rbc-ams41e

Reset search

  • ERROR CODE E-D4 WILL NO OPERATE ON HEAT...COULD IT BE FILTER FAULT Submitted on 14-5-2022 at 00:44

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba RBC-AMS41E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba RBC-AMS41E in the language / languages: English as an attachment in your email.

The manual is 2,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Toshiba RBC-AMS41E

Toshiba RBC-AMS41E Quick start guide - English - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info