Toolland | www.toolland.be 3
standards need to be complied with when
installing the appliance.
The installation of the smoke outlet must
be as vertical as possible, avoiding the
use of joints, angles and deviations.
If the installation is connected to a
masonry chimney pipe we recommend
the tubes reach the exterior exit. If the
smoke outlet is via tubing only at least
three meters of vertical tubing are
recommended.
Important: the installation of this stove
must be carried out by a qualified
professional.
The ventilation opening must never be
obstructed.
Important: the woodstove must be
installed in a well ventilated place.
It is advisable to have at least one
window in the same room as the stove
which can be opened.
The tube connections should be sealed
with a refractory putty to prevent soot
from falling through the joints.
Do not position the stove near
combustible walls. The stove should be
installed on a non combustible floor
surface, if not a metal plate covering the
bottom surface area of the stove must be
placed underneath it and extend further
than 15 cm at the sides and 30 cm at the
front.
Whilst the stove is in use remove any
material nearby which could damaged by
the heat: furniture, curtains, paper,
clothes…
Please consider keep ease of access for
the cleaning of the product, smoke outlet
and chimney smoke outlet.
If you intend to install your stove near an
inflammable wall we advise you to leave
a minimum distance to facilitate cleaning.
This stove is not suitable for installation
in any chimney system shared by other
sources.
The stove should be installed on flooring
with adequate support.
If your current floor does not comply with
this criterion, it should be adapted with
appropriate measures (for example a
weight distribution plate).
FUEL
Use only dry wood with a maximum
moisture content of 20%.
Wood with a moister content higher than
50 or 60% does not heat and combusts
very badly, and creates a lot of tar,
releases excessive amounts of vapour
and deposits excess sediments onto the
stove, glass and smoke outlet.
The fire should be lit using special fire
lighters, or paper and small pieces of
wood.
Never try to light the fire using alcohol or
similar products.
Do not burn plastic materials or greasy
products that can pollute the
environment and lead to risks of fire due
to obstruction of the pipes.
TECHNICAL SPECIFICATIONS
capacity
125 m²
steel thickness
1.5 mm
total height
70 cm
smoke outlet diameter
12 cm
weight
42 kg
heat resistant paint
800 °C
dimensions:
upper chamber
50.5 x 20 x 20 cm
lower chamber
61.5 x 30 x 30.5 cm
MAINTENANCE
Never clean the stove while it is in use.
It is also important to clean the smoke
outlet tubing periodically and check there
are no blockages before relighting fuel
after a long period of non-use.
At the start of each season a professional
should carry out a revision of the
installation.
In the event of a fire in the smoke outlet,
close all air draughts if possible and
contact the authorities immediately.
Any replacement parts which you may
need must be recommended by us.
WARRANTY
Refer to the enclosed guarantee conditions
for the terms and conditions of guarantee.
ENVIRONMENT
Should your device need replacement after
extended use, do not put it in the domestic
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toolland TC80100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toolland TC80100 in the language / languages: English, German, Dutch, French, Portuguese, Spanish as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info