19. MUTE SENSE control (PRIORITY 1, PRIORITY 2)
Adjust the threshold (sensitivity) of the mute function of the PRIORITY 1, PRIORITY 2 inputs. In other
words, if PRIORITY 1, PRIORITY 2 input signal exceed the threshold that set by MUTE SENSE, it will
mute the LINE 1, LINE 2, LINE 3, LINE 4 signal to CH1, CH2, CH3, CH4 outputs. Rotate clockwise will
raise the sensitivity, counter-clockwise will lower the sensitivity.
20. HOLD TIME control (PRIORITY 1, PRIORITY 2)
Adjust the recovery time of the LINE 1, LINE 2, LINE 3, LINE 4 to CH1, CH2, CH3, CH4 outputs. Rotate
clockwise will increase the recovery time (maximum 10sec), counter-clockwise will decrease the
recovery time (minimum 50ms)
21. PRIORITY FUNCTIONAL DIP SWITCH (PRIORITY 1, PRIORITY 2)
Control the functionality of the PRIORITY 1 and PRIORITY 2
Switch No. ON OFF
1 PRIORITY 1/2 can be switched to CH1 output PRIORITY 1/2 cannot be switched to CH1 output
2 PRIORITY 1/2 can be switched to CH2 output PRIORITY 1/2 cannot be switched to CH2 output
3 PRIORITY 1/2 can be switched to CH3 output PRIORITY 1/2 cannot be switched to CH3 output
4 PRIORITY 1/2 can be switched to CH4 output PRIORITY 1/2 cannot be switched to CH4 output
5 The mute function is controlled by the PRIORITY
1/2 input signal or manual mute (16)
The mute function is only controlled by the
manual mute (16)
6 PRIORITY 1/2 input gain switch to MIC level PRIORITY 1/2 input gain switch to LINE level
22. PRIORITY MIX1+2 switch
Control the input mode of the PRIORITY 1/2
ON OFF
PRIORITY 1 and PRIORITY 2 will be mixed and output
to CH1, CH2, CH3, CH4 when mute activated. The
PRIORITY FUNCTIONAL DIP SWITCH (20), MUTE
SENSE control (18), HOLD TIME control (19) will be
followed by PRIORITY 1’s setting
The PRIORITY 1 has the higher priority level than
PRIORITY 2. When There is mute function activated.
Unit will output PRIORITY 1’s input first.
23. EQ BANKS and PRESETS SELECTION
The 2-bit DIP switch select the bank of respect to the 16 EQ presets. Total 4 banks.
The 4-bit rotary switch selects 16 EQ presets from each banks.
Note: The functionality of CH2, CH3, CH4 is the same as CH1.
Please see page 23, "11.2 EQ preset selections" for more details.
24. HPF SWITCH (*)
Control the activation of HPF (High Pass filter) on outputs.
ON OFF
The CH1, CH2, CH3, CH4 will has 50Hz, -12dB/oct. high
pass filter on output. This is useful to protect the speaker
when the transformer of the distribute speaker couldn’t
handle low frequency.
The output frequency response is flat from 20Hz to
20kHz.
25. REMOTE TERMINALS (CH1, CH2, CH3, CH4 remote controls)
RJ45 connector, use for connecting the remote module WP-700.
After connecting WP-700 could provide the following functionality:
1) Switch the input source LINE 1, LINE 2, LINE 3, LINE 4 to CH1, CH2, CH3, CH4 outputs.
2) Adjust the volume of connected channel.
Note: When the WP-700 is connected, the OUTPUT LEVEL CONTROL (3) on front panel and INPUT
SELECT SWITCH (10) won’t be functional. It means this two function will follow WP-700 setting. Also,
the REMOTE INDICATOR (8) will light.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toa MA-725F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toa MA-725F in the language / languages: English as an attachment in your email.

The manual is 2,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info