Truly Instrument Ltd. 2/F., Thomson HC STAB -XTOM
Chung Shun Knitting Centre, 1-3 Wing Yip St, Kwai Chung, Parc Lumière, 46 avenue des Frères Lumière
NO CONTACT EAR THERMOMETER TTET350 N.T., HONG KONG 78190 Trappes - France
PRODUCT DESCRIPTION AND
RECOMMENDATION
This non contact ear thermometer has been
designed for taking temperature of human body
trough eardrum which is the best way to get
precise temperature. Eardrum shares blood
supply with hypothalamus which is the
temperature control center in the brain.
For accurate result, clean probe and lens with
a cotton swab.
Ensure the probe is facing eardrum in straight
line.
Pull ear smoothly to flatten ear canal.
This thermometer can be only use at
temperature between 10°C and 40°C.
Temperatures measured from left and right
ears are different, there could be a slight
difference; in consequence, this is much
better to take the temperature from the same
ear.
Keep your thermometer away from water and
from any source of heat, including direct
sunlight.
SECURITY
This thermometer can be only used for which
it has been designed as explained in the
instruction booklet.
Use of this thermometer cannot replace in any
case doctor’s advice, especially when
temperature is too high or too low.
Do not immerse the unit into water.
If you have a problem with this appliance,
don’t try to repair it yourself and do not
attempt to disassemble the thermometer.
MAINTENANCE
Clean your device with a soft dry cloth, lens
with a cotton swab moistened with alcohol.
Keep your thermometer away from water and
from any source of heat, including direct
sunlight.
Remove batteries from your device if you
don’t use for a long time.
PRODUCT DESCRIPTION
Functions
2-LCD
screen
3-Measurement
button
Functions
5-Battery
cover
USING THE PRODUCT
Inserting and changing batteries
When the power is low, the low battery signal
is displayed, you have to replace batteries.
Press and push the battery cover to open it.
Remove the old batteries and insert the new
batteries ensuring that the negative and
positive ends are at the right place.
Replace the cover
First use
Press power/memory button, signal beep
when your device is ready.
All icons display in a first step, then backlight
red, orange, green, then last measurement.
Your device is ready when icon °C is blinking.
Taking temperature
Start measuring pull ear smoothly to flatten
ear canal and place the probe facing eardrum
in straight line.
Press measurement button until you hear the
beep signal.
When the measurement is complete, the
temperature will be displayed with colored
backlight:
o Green: 35,8°C-37,3°C
o Orange: 37,4°C-38°C
o Red: 38,1°C-42,2°C
o No back light: 34°C-35,7°C
If you need to take another measurement,
allow an interval of 8 seconds until the signal
°C flashes.
To turn off your thermometer, push
power/memory button until the “OFF” signal is
displayed.
Memory
Your thermometer Thomson TTET350 stores
the last 8 temperature readings.
When power on, press power/memory button
to recall first reading. Repeat pressing
power/memory button to recall the next
readings.
To remove all data in memory, press both
power/ memory button and measurement
buttons and hold during 3 seconds. The signal
“Clr” display and the memory will be deleted.
Explanations of display symbols “Er”
Origin of display
“Er” on display
Explanations /Solutions
Er1
Issue with ambient temperature/
Allow the thermometer remain in
room temperature for 30 minutes
Er2
Sensor error/Contact after sales
service.
Er3
Memory error/Contact after
sales service.
Technical specifications
Operating temperature range: 32°C to 42,5°C.
Measuring accuracy: +/- 0,3°C
Measuring time: 1 second
Graduation: 0,1°C
Memory: 8
Operating conditions: 10 to 40°C, humidity
<85%
Storage condition: -20°C to 55°C
Power supply: 3V DC (2 batteries AA)
Compliance
This thermometer complies with the
manufacturing standards of European medical
device directive MDD (93/42/EEC).
EN60601-1 :1998, EN124070-5, ASTM
E1965-1998
CE0123
European representative : STAB XTOM 46
avenue des Frères Lumière 78190 TRAPPES
Manufacturer : TRULY Instrument Ltd, 2/F,
Chung Shun Knitting centre, 1-3 Wing Yip St,
Kwai Chung, N.T HONG KONG
Environmental protection: Deposit empty
batteries in a container designed for this
purpose so they may be collected and recycled.
Do not mix empty batteries with new batteries.
At the end of its lifespan, send this product to
an electrical and electronic device equipment
point, in line with European directive
2002/96/EC-WE
ENGLISH
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thomson TTET 350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thomson TTET 350 in the language / languages: English, German, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 0,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info