459808
16
Zoom out
Zoom in
Previous page
1/16
Next page
Special voltage TR top2 24 V
The devices are designed for switching mains and low voltage (SELV, PELV, FELV).
TR 612 top2 24 V, TR 622 top2 24 V, TR 641 top2 RC 24 V, TR 642 top2 RC 24 V
With these devices the type of low voltage must correspond to low voltage type of the supply
voltage (SELV = SELV, PELV = PELV, FELV = FELV).
If the switch output is 230 V, the time switch can be operated using low function voltage but not SELV as
supply voltage.
Lay the control cable separately from the load power.
TR 610 top2 24 V, TR 611 top2 24 V, TR 611 top2 RC 24 V
The devices are approved for switching SELV and mains voltage.
The external outputs are designed for operating voltage of 12-24 V AC and DC and not for 230 V.
310 357
~
~
~
2,5mm
2
50-60Hz
R 8a- 30T
C1/C2
16(2)A 250V~
8mm
12-24V UC
~
Data
MENU
OK
1
2
0 6
12
18
24
TR 642 top2 RC
Ext1 Ext2
~
+
C
1
C2
~
2,5mm
2
0,5mm -
2
8mm
12-24V UC
50-60Hz
R 10a- 30T
16(2)A 250V~
1
C1
2
3
MENU
OK
0 6
12
18
24
TR 610 top2
~
+
~
+
~
+
~
+
12-24V UC
~
~
2,5mm
2
0,5mm -
2
50-60Hz
R 10a- 30T
C1/C2
16(2)A 250V~
8mm
1
C1
2
3
1
C1
2
3
Ext 2Ext 1
4
C2
5
6
4
C2
5
6
MENU
OK
1
2
0 6
12
18
24
TR 622 top2
~
+
~
+
C
1
C2
12 - 24 V
12 - 24 V
12 - 24 V
C2
C
1
~
~
+
12-24V UC
~
~
2,5mm
2
0,5mm -
2
50-60Hz
R 10a- 30T
C1/C2
16(2)A 250V~
8mm
1
C1
2
3
Ext 2Ext 1
4
C2
5
6
MENU
OK
1
2
0 6
12
18
24
TR 622 top2
~
+
~
+
C
1
C2
12 - 24 V
~
~
~
2,5mm
2
50-60Hz
R 8a- 30T
C1/C2
16(2)A 250V~
8mm
12-24V UC
~
Data
MENU
OK
1
2
0 6
12
18
24
TR 642 top2 RC
Ext1 Ext2
~
+
C
1
C2
~
2,5mm
2
0,5mm -
2
8mm
12-24V UC
50-60Hz
R 10a- 30T
16(2)A 250V~
1
C1
2
3
MENU
OK
0 6
12
18
24
TR 610 top2
~
+
~
+
~
+
~
+
12-24V UC
~
~
2,5mm
2
0,5mm -
2
50-60Hz
R 10a- 30T
C1/C2
16(2)A 250V~
8mm
1
C1
2
3
1
C1
2
3
Ext 2Ext 1
4
C2
5
6
4
C2
5
6
MENU
OK
1
2
0 6
12
18
24
TR 622 top2
~
+
~
+
C
1
C2
12 - 24 V
12 - 24 V
12 - 24 V
C2
C
1
TR 610 top2 24 V TR 622 top2 24 V TR 642 top2 RC 24 V
Electrical connection
GB
Permissible operating voltage: 12 V–24 V / 5060 Hz +10 % 15 %, 12 V–24 V DC +10 % –15 %
Switching capacity: 16 A, 250 V~ cos ϕ = 1; 2 A, 250 V~ cos ϕ = 0.6
Incandescent lamp load, halogen load: 1400 W at 230 V or 6 A
Flashlight (EB) 230 V: 180 W
Compact lamp (EB) 230 V: 7 x 7 W, 6 x 11 W, 5 x 15 W, 5 x 20 W, 4 x 23 W
Fluorescent lamps, parallel-corrected 230 V: 1 x 58 W / 7 µF, 2 x 36 W (4.5 µF each), max. 12 µF
Halogen metal halide lamps 230 V: 1 x 70 W (12 µF)
Standby output min. Power consumption typ.
0.3 W 1.0 W (TR 612 top2 24 V, TR 622 top2 24 V)
0.3 W 0.7 W (TR 610 top2 24 V, TR 611 top2 24 V)
0.9 W 1.3 W (TR 611 top2 RC 24 V)
1.5 W 2.5 W (TR 642 top2 RC 24 V)
1.5 W 2.0 W (TR 641 top2 RC 24 V)
Mode of operation: Type 1 BSTU in accordance with EN 60730-1
Pollution degree: 2
Rated impulse voltage: 4 kV
Protection class: II for supply with FELV and/or mains switching
III for supply with SELV and switching of SELV
Protection rating: IP 20 in accordance with EN 60529
Power reserve: 8 years at 20 °C ℃
610 4 100
611 4 100
611 4 300
612 4 100
622 4 100
641 4 300
642 4 300
Technical data
The technical data and the section on the "electrical connection" of 230 V devices
(see operating instructions) do not apply to devices with special voltage.
External outputs
Serviceadresse
Theben AG
Hohenbergstr. 32
72401 Haigerloch
DEUTSCHLAND
Fon +49 (0) 74 74/6 92-0
Fax +49 (0) 74 74/6 92-150
Hotline
Fon +49 (0) 74 74/6 92-369
Fax +49 (0) 74 74/6 92-207
hotline@theben.de
Addresses, telephone numbers etc.
www.theben.de
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Theben Termina TR 622 top2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Theben Termina TR 622 top2 in the language / languages: English as an attachment in your email.

The manual is 1,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Theben Termina TR 622 top2

Theben Termina TR 622 top2 User Manual - German - 28 pages

Theben Termina TR 622 top2 User Manual - Dutch - 14 pages

Theben Termina TR 622 top2 User Manual - French - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info