WEATHER TENDENCY INDICATOR
Working together with the weather icons is the weather tendency indicators (arrow
located on the left and right sides of the weather icons). When the indicator points
upwards, it means that the air-pressure is increasing and the weather is expected to
improve, but when indicator points downwards, the air-pressure is dropping and the
weather is expected to become worse.
Taking this into account, one can see how the weather has changed and is expected to
change. For example, if the indicator is pointing downwards together with cloud and sun
icons, then the last noticeable change in the weather was when it was sunny (the sun
icon only). Therefore, the next change in the weather will be cloud with rain icons since
the indicator is pointing downwards.
Note: Once the weather tendency indicator has registered a change in air pressure,
it will remain permanently visualized on the LCD.
AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH BAROMETRIC
PRESSURE TREND)
The LCD also shows the relative air pressure value and the air pressure history.
Press the SET key to toggle between Mode1 and Mode2 of the display.
Mode 1: the bar graph displays the air pressure history of the past 24 hours in
seven steps. The horizontal axis represents the last 24 hours of air pressure
recording (-24, -18, -12, -9, -6, -3 and 0 hour).
Mode 2: the bar graph displays the air pressure history of the past 72 hours in
seven steps. The horizontal axis represents the last 72 hours of air pressure
recording (-72, -48, -36, -24, -12, -6 and 0 hour).
The vertical bars are plotted at each of the nine steps and give the trend over the
recorded period. The 0 hour vertical bar will always display at the midline height to
indicate the current air pressure. The varying height of bars inn other columns on the
graph indicate a relative change in air pressure up or down from the previous
measurement.
New pressure measurements are compared to previously recorded pressure
measurements. The pressure change is expressed by the difference between the
current ("0h") and the past readings in divisions of ±0.06 inHg or ±2 hPa. If the bars are
rising from left to right, this indicates that the weather is getting better due to an
increase in air pressure. If the bars are falling from left to right, this indicates that the
weather is expected to get worse due to a drop in air pressure.
At every full hour, the current air pressure is used as a basis for the display of a new
graph bar. The existing graph is then moved one column to the left.
Note: For accurate barometric pressure trend, the Weather Center should operate at
the same altitude. For example, it should not be moved. Should the unit be moved, for
instance from the ground to the second floor of the house, the readings for the next 48-
60 hours shall be discarded.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA Opus 35.1112 IT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA Opus 35.1112 IT in the language / languages: English as an attachment in your email.

The manual is 1,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TFA Opus 35.1112 IT

TFA Opus 35.1112 IT User Manual - German - 34 pages

TFA Opus 35.1112 IT User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info