RADIO CONTROLLED ALARM CLOCK
WITH
AIR QUALITY MONITOR
Instructions manual
Cat. No. 60.2527.10
Thank you for choosing this instrument from TFA.
Our "Big Air Monitor" shows you how used and polluted your air really
is. It allows you then to ventilate in an energy efficient way and to
ensure a healthy indoor climate at home or in the office.
Headaches, dizziness and fatigue are often due to an excessive
concentration of volatile organic compounds from natural and artificial
sources of emissions.
The air quality sensor detects more than 5,000 substances in the air
which can be harmful to people, for example formaldehyde, solvents,
carbon monoxide, methane or cigarette smoke.
The device displays the air quality with different levels and warns of
invisible dangers!
Important!
Please keep in mind that after setting up the instrument a reliable
value is displayed only after about 5 days. The sensor has to
adjust itself to the actual conditions at the installation site and
find a reference level.
Until this process is complete, the instrument initially shows
higher values.
BEFORE YOU USE IT
Please make sure to read the instruction manual carefully.
This information will help you to familiarise yourself with your new
device, to learn all of its functions and parts, to find out important
details about its first use and how to operate it, and to get advice in
the event of faults.
Following and respecting the instructions in your manual will prevent
damage to your instrument and loss of your statutory rights arising
from defects due to incorrect use.
We shall not be liable for any damage occurring as a result of not
following these instructions. Likewise, we take no responsibility
for any incorrect readings and for any consequences which may
result from them.
Please take particular note of the safety advice!
Please keep this instruction manual for future reference.
SCOPE OF DELIVERY:
Radio controlled alarm clock with air quality monitor
Instruction manual
FIELD OF OPERATION AND ALL THE BENEFITS OF
YOUR NEW INSTRUMENT AT A GLANCE:
• Radio-controlled clock with highest precision and manual
setting option
• Alarm with snooze function
• Date display
• Air quality monitor with various levels
• Acoustic and visual alarm function
• Indoor temperature and humidity
• Backlight
FOR YOUR SAFETY:
The product is exclusively intended for the field of application
described above. The product should only be used as
described within these instructions.
Unauthorised repairs, modifications or changes to the product
are prohibited.
This product is not to be used for medical purpose or for public
information; it is only intended for home use.
Caution!
Risk of injury:
Keep this instrument and the batteries out of the reach of
children.
Batteries must not be thrown into the fire, short-circuited, taken
apart or recharged. Risk of explosion!
Batteries contain harmful acids. Low batteries should be
changed as soon as possible to prevent damage caused by a
leaking battery. Never use a combination of old and new
batteries together or batteries of different types. Wear
chemical-resistant protective gloves and glasses when
handling leaking batteries.
! Important information on product safety!
Do not place your product near extreme temperatures,
vibrations or shocks.
Protect it from moisture.
ELEMENTS:
The air quality monitor
SETTING UP:
1. Open the battery compartment at the back of the device. Insert
two new batteries 1,5V C, IEC LR14. Make sure the polarities
are correct. Close the battery compartment again.
2. When the batteries are inserted, all the segments of the LCD
will light up briefly and a “beep” will sound.
3. The device will now start receiving the DCF time signal. After
approximate 3 to 10 minutes, the DCF time will be displayed.
4. If there is no DCF reception possible after 10 minutes, you
have also the possibility to set the time manually (see: Manuel
settings).
RADIO-CONTROLLED TIME RECEPTION
The time base for the radio-controlled time is a cesium atomic clock
operated by the Physikalisch Technische Bundesanstalt
Braunschweig. It has a time deviation of less than one second in one
million years. The time is coded and transmitted from Mainflingen near
Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a
transmitting range of approximately 1,500 km. Your radio controlled
clock receives this signal, converts it to show the precise time.
Changeover from summer time or winter time is automatic. The quality
of the reception depends mainly on the geographic location. Normally
there should be no reception problems within a 1,500 km radius
around Frankfurt.
The DCF reception always takes place at 02:00 and 03:00 am. If the
reception is not successful received at 03:00 am, the next attempt will
be held at 02:00 am the next day.
Please take note of the following:
The recommended distance to any interfering sources like
computer monitors or TV sets is at least 1.5 - 2 meters.
Inside Ferro-concrete rooms (basements, superstructures), the
received signal is naturally weakened. In extreme cases,
please place the unit close to a window to improve the
reception.
During nighttime, the atmospheric interference is usually less
severe and reception is possible in most
cases. A single daily
reception is adequate to keep the accuracy deviation under 1
second.
BUTTON FUNCTIONS:
The device has 5 easy-to-use buttons:
By each button press the backlight will be activated for about 10
seconds.
LCD SCREEN
Press the SET button in normal mode to show the calendar for
about 6 seconds.
Press the MODE button in normal mode to toggle between:
Equivalent CO
2
ppm display, seconds and alarm display.
AIR QUALITY INDICATOR
* The air quality value shown, after sensor conditioning, may differ +/-
250 ppm.
The air quality sensor detects more than 5,000 harmful substances in
the air.
The measured values are attributed to CO
2
- equivalent units of ppm
to maintain compatibility with CO
2
ventilation standards.
Note:
An Equivalent CO
2
ppm value will appear after 30 minutes after setup.
The instrument initially shows higher values. The device adjusts itself
to the actual conditions at the installation site and finds a reference
level. A reliable value is displayed only after about 5 days located at
the same place.
AIR QUALITY SYMBOL
The air quality symbol (arrow) is located on the bottom of the LCD.
The bar graph measures from GOOD (green) until BAD (red) and is
printed on the edge of the housing.
Levels Equivalent CO
2
ppm
GOOD (level 1) 450 – 600ppm
Level 2 650 – 800ppm
Level 3 850 – 1000ppm
Level 4 1050 – 1200ppm
Level 5 1250 – 1500ppm
Level 6 1550 – 1800ppm
Level 7 1850 – 2100ppm
Level 8 2150 – 2400ppm
BAD (level 9) ≥ 2450ppm
MANUAL SETTINGS:
The following manual settings can be done in the setting mode:
Time zone setting
DCF ON/OFF setting
12/24 hour time setting
Manual time setting
Calendar setting
Snooze function setting
ºC / ºF temperature display setting
Air quality alert setting
Press and hold the SET button for about 3 second to enter the setting
mode:
TIME ZONE SETTING
The time zone default is "0h". To set a different time zone:
1. 0h starts flashing.
2. Use the +button to set the time zone. The range runs from 0,
1, 2…until -12, and then from 12, 11, 10 back to 0.
3. Confirm with the SET button and enter the Time reception
On/Off setting.
TIME RECEPTION ON/OFF SETTING
In area where is no DCF reception is possible, you have also the
possibility to deactivate the DCF reception manually (OFF). The clock
will then work as a normal quartz clock (Default is ON).
1. The symbol “ON” and the reception symbol will start flashing on
the LCD.
2. Use the + button to deactivate (OFF) the time reception
function if necessary.
3. Confirm with the SET button and enter the 12/24 hour time
display setting.
Note:
If the time reception function is deactivated (OFF) manually, the clock
will not attempt any reception of the radio-controlled time (DCF time)
as long as the time reception will be activated (ON) again. If the time
reception is deactivated (OFF) the DCF symbol disappears.
12/24 HOUR TIME DISPLAY SETTING
1. “12hr” or “24hr” flashes in the LCD (default is 24hr).
2. Press the + button to select the “12hr” or “24hr” display mode.
3. Confirm with the SET button and enter the Manual time
setting.
Note:
When 24h time display is selected, the calendar format will be date
and month display. When 12h time display is selected, the calendar
format will be month and date display.
MANUAL TIME SETTING
In case the device is not able to attempt the radio-controlled time
(disturbances, transmitting distance, etc.), the time can be manually
set. The clock will then work as a normal quartz clock.
To set the clock:
1. The hour digits will be flashing in the display.
2. Use the + button to adjust the hours. Press the SET button to
go to the minute setting.
3. The minute will be flashing. Press the + button to just the
minutes.
4. Confirm with the SET button and enter the Calendar setting.
Flashing
Flashing
Flashing
S
ET button
ALARM button
+ button
MODE
button
SNOOZE button
Flashing
Function buttons
LCD display
Function button
Air quality indicator
Bar graph
Equivalent CO
2
ppm (parts per
million)*
Battery
Sensor
Time
Low battery icon
Indoor temperature
in ºC/ºF
Alarm time /
Equivalent CO
2
ppm / seconds
display
Indoor relative
humidity % RH
Alarm icon
DCF Tower icon (for time reception)
Air quality indicator
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA 60.2527 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA 60.2527 in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TFA 60.2527

TFA 60.2527 User Manual - German - 2 pages

TFA 60.2527 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info