Congratulations on the purchase of the product. We hope than you can make use of this product for a long time and that it helps you
with your work. Information that are useful and important for understanding the function are highlighted in the instructions text.
Powered by a replaceable lithium battery, the thermometer is a handy, temperature measurement device for a whole range of
measurement and control applications.
1. LCD
2. ON/HOLD
3. °C/°F :
4. Thermocouple Socket
5..Battery Cover
OPERATION
1.Power on :
To switch the
thermometer on, keep
KeyON/HOLD(2) pressed
for approximately one
second.
2. Display LCD
All necessary information is displayed on an LCD.
The individual symbols have the following meanings:
2.1 Display for current measured values
2.2 Minus sign (negative measured values)
2.3 Battery status indicator
2.4 HOLD“ -- Auto shut down after 15 sec
2.5 Temperature unit
3 Measuring temperature
Select the required unit of measurement °C or °F.
°C /°F can be changed only when “Hold” is shown
4.Position the tip of the thermocouple where you wish to measure the
temperature and press ON/HOLD key. Wait till the temperature has
stabilized and subsequently read the value from the display. Now, the
current temperature is displayed for about 4 min. If you press
ON/HOLD a second time, the word “HOLD“ appears in the LCD.
*The last measured value is frozen and the thermometer deactivates
itself automatically after about 15 seconds to
save battery power.
CAUTION
The thermometer should be protected from the following:
1.Electro Static Discharge
2.”Thermal shock” caused by large or abrupt ambient temperature changes
- allow 30 minutes for unit to stabilize before use when exposed to “thermal shock”.
3.Do not leave the unit on or near objects of high temperature.
4.Keep out of reach of all children.
STORAGE & CLEANING
Clean the device with a damp cloth. Do not use any solvents such as Aceton as they corrode the plastic. Isopropyl alcohol may be
used to disinfect. Do not submerge any part of the thermometer. The thermometer should be stored at room temperature
between 20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0
o
C(32°F) or +50
o
C (122°F). The thermometer
should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature.
Error 5~9, for all other error messages it is necessary to reset the thermometer. To reset it, turn the instrument
off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error
message remains please contact the Service Department for further assistance.
」「
Hi or Lo is displayed when the temperature being measured is outside of the
measurement range.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements are
not possible
BATTERY REPLACEMENT
When the Low Battery icon indicates the battery is low, the battery should be replaced immediately with a CR2032 lithium cell. The
battery is located under the twist cover at the rear of the thermometer. Please note: It is important to turn the instrument off before
replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery properly and keep away from children.
SPECIFICATION
-64 to +1400
o
C (-83.2 to +1999
o
F) - K type, Socket
0~50°C (32~122°F)
+/-1% of reading or 1°C (1.8°F) whichever is greater
0.1°C/0.1°F
TCP:100 hours continuous use
78 x 43 x 20 mm(3×1.7×0.8 inch)
40.15 grams(1.42 oz) including a CR2032 lithium cell
** The thermometer will automatically shut off if left idle for more than 15 sec.
Caution: The measure range is for thermometer only. User should choose proper probe types for different kinds of
application. Please make sure the target to be measured will not exceed the temperature range of the probe
to avoid permanent damage of the thermocouple probe.
Caution: To avoid electric shock and thermometer damage, do not measure live circuit where voltage exceeding 24V
AC RMS or 60V DC with the thermocouple probe.
EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA 31.1034 Mini-K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA 31.1034 Mini-K in the language / languages: English as an attachment in your email.

The manual is 0,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TFA 31.1034 Mini-K

TFA 31.1034 Mini-K User Manual - German - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info