658264
2
Zoom out
Zoom in
Previous page
1/2
Next page
Temperature transmitter
1. Functions
Additional temperature transmitter for wireless
weather stations (e.g. 35.1110)
For the wireless transmission of outdoor temperature
and DCF time (433 MHz), transmission range up to
50 m (free field)
Also for temperature control of remote rooms,
f. e. children’s room, wine-cellar
2. Elements Fig. 1
D1: Transmission indication LED
D2: Wall mount hole
D3: Battery compartment holders
D4: Channel-button
D5: °C/°F button
D6: RESET button
3. Getting started
Place the display unit and the transmitter on a desk
with a distance of approximately 1.5 meter. Check that
no other electronic devices are close.
Take the display unit into operation according to the
manual of the display unit.
Open the battery compartment of the transmitter by
pushing inwards the two latches at the bottom and
insert 2 x AA 1.5 V batteries, observing the correct
polarity.
The LED indicator of the transmitter is blinking and the
transmitter is set to channel 1 by default.
After the sensor is powered up, it will first transmit the
temperature and then the sensor will start radio con-
trolled time reception. During the reception period
(maximum 10 minutes), no weather data will be trans-
mitted.
Please take note of the following:
The radio controlled time receiver is built inside the
thermo-sensor. It is recommended to keep distance to
any interfering sources and ferro-concrete buildings.
During night-time, the atmospheric disturbances are
usually less severe and reception is possible in most
cases. A single daily reception is adequate to keep the
accuracy deviation below 1 second.
4. Positioning of the transmitter
Choose a shady and dry position for the transmitter.
(Direct sunshine falsifies the measurement and conti-
nuous humidity strains the electronic components
needlessly)
Check the transmission of 433 MHz signal from the trans-
mitter to the display unit (transmission range 50 m free
field). Within ferro-concrete rooms (basements, super-
structures), the received signal is naturally weakened.
If necessary choose another position for transmitter
and/or display unit.
5. Additional transmitters
For having more than one external transmitter, select a
different channel (2 to 3) for every transmitter by pres-
sing the “CH” button on the transmitter while the
transmission indication LED is flashing. Press once for
channel 2 and twice for channel 3 right after the star-
ting up of the transmitter. The LED is flashing once for
channel 1, twice for channel 2 and three times for
channel 3.
Press and hold the “B1” button on the display unit for
2 sec. to start initialization manually. The channel num-
ber on the LCD of the display unit flashes and the new
transmitter will be received automatically (model
35.1110).
6. Battery replacement
Caution!
Risk of injury:
Keep the batteries out of reach of children.
Batteries must not be thrown into the fire, short-circui-
ted, taken apart or recharged. Risk of explosion!
Batteries contain harmful acids. Low batteries should
be changed as soon as possible to prevent damage cau-
sed by a leaking battery. Remove the batteries if you do
not use the product for a lengthy period. Never use a
combination of old and new batteries together nor bat-
teries of different types (e.g. zinc-carbon and alkaline
batteries). Wear chemical-resistant protective gloves
and glasses when handling leaked batteries.
7. Waste disposal
This product has been manufactured using high-grade
materials and components which can be recycled and
reused.
Never throw flat batteries and rechargeable
batteries in household waste. Never use a
combination of old and new batteries
together nor batteries of different types (e.g.
zinc-carbon and alkaline batteries).
As a consumer, you are legally required to take
them to your retail store or to appropriate
collection sites according to national or local
regulations in order to protect the environ-
ment.
The symbols for the heavy metals contained
are: Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with
the EU Waste Electrical and Electronic Equip-
ment Directive (WEEE).
Please do not dispose of this product with
other household waste. The user is obligated
to take end-of-life devices to a designated
collection point for the disposal of electrical
and electronic equipment, in order to ensure
environmentally-compatible disposal.
8. Specifications
Transmitter:
Measuring range: -20°...+60 °C /
(transmitter) -4°...+140 °F, °C/°F-switchable
Resolution: 0.1°C / 0.2°F
Transmission frequency: 433 MHz
Transmission time: 60 – 75 seconds
Transmission signal: Once - Channel 1
Twice - Channel 2
Tree times - Channel 3
Transmission range: Max. 50 m
Power consumption: 2 x 1.5V AA
Housing dimension: 75 x 25 x 93 mm
TFA Dostmann GmbH & Co. KG, Zum Ottersberg 12, D-97877 Wertheim
No part of this manual may be reproduced without written consent of
TFA Dostmann. The specifications of this product may change without
prior notice.
DECLARATION OF CONFORMITY
We herewith declare that this wireless transmission device conforms to
the essential requirements of the R&TTE Directive 1999/5/EC.
A copy of the signed and dated Declaration of Conformity is available
on request from info@tfa-dostmann.de.
TFA Dostmann GmbH & Co.KG, D-97877 Wertheim / www.tfa-dost-
mann.de
04/11
Kat. Nr. 30.3186
Bedienungsanleitung
Instruction manual
Fig. 1
Temperature transmitter
Temperature transmitter
D 1
D 7
D 4
D 2
D 3
D 6
D 6
D 5
Front
Back
Bottom
TFA Anl_No. 30.3186 09.05.2011 11:57 Uhr Seite 2
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TFA 30.3186 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TFA 30.3186 in the language / languages: English, German as an attachment in your email.

The manual is 0,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info