for Hand-held Measuring Instrument P200B / Kat. No. 30.1014
Commissioning
Remove the protective film from the film keyboard. Open the battery
compartment on the rear of the instrument and, if present, remove the battery
circuit breaker strip. The instrument switches itself on and is immediately ready
for operation after inserting the batteries.
Button (ON/OFF)
The measuring instrument can be switched on and off with this button.
AUTO-OFF function
the instrument switches itself off automatically after approx. 15 minutes if no
button has been pressed during this time.
Button (°C/°F)
This button is provided for switching-over the display between °C and °F. The
currently active temperature units are retained even after switch-off.
Button(MODE)
Press the MODE-key once in normal mode and the hold-function is activated
(indicated by HOLD). Press the MODE-key again and the maximum temperature
is shown since the last reset (indicated by MAX). Press the MODE-key again
and the minimum temperature is shown since the last reset (indicated by MIN).
Press the MODE-key again to return to normal mode. To clear the maximum and
minimum memory, press and hold the MODE-key for 3 seconds in the
corresponding mode while MAX or MIN is displayed (indicated by ---). Press the
MODE-key again to return to normal mode.
Battery replacement
To open the battery case remove the both screws on the backside of the
instrument.
Technical Data
Measuring range -40 °C to 120 °C
Cable: max. 80 °C
Resolution 0.1 °C through the measuring range
Accuracy: +- 1 °C from -10 °C to 100 °C otherwise +- 2 °C
Sensor NTC resistor
Permissible operating
temperature range O °C ..+ 40 °C
Operating voltage 2 size AA cells. 1.5V each
Battery life approx. 1 year
Case dimensions approx. 95 x 60 x 18 mm (L x W x H)
Weight approx. 130 g
Attention: The probe cable is not heat resistant.
Need help? Post your question in this forum.
Report abuse
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for TFA 30.1014 P200B at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of TFA 30.1014 P200B in the language / languages: English as an attachment in your email.
The manual is 0,05 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.