622566
1
Zoom out
Zoom in
Previous page
1/2
Next page
DIGITAL
ELECTRONIC
SAFE
Mod. “GTR” with “TIME DELAY”
FEATURES
High performance microprocessor.
Possible combinations: 10 billion.
Power supplied by a voltage transformer and 4 x LR6 AA 1.5-v alkaline batteries.
Alphanumeric keyboard with 12 keys: 10 keys with numbers from 0 to 9 and 26 letters
“ENTER” key to confirm code set.
The keyboard is of the membrane type with four dedicated LEDS, and contacts for external
emergency power supply in the event of internal batteries being flat.
Internal button for programming new personal code.
DIGITS THAT CAN BE SET: minimum 4 – maximum 10 digits in permanent memory
(the “ENTER” and “ON” keys are not valid in the combination)
INTRODUCTION
ALL SAFES ARE PROVIDED WITH SERVICE CODE “1111” AND NO TIME DELAY.
Before installing the safe, check that it works properly and read the instructions carefully to
understand the operation.
Every time a key is pressed the green “OK” LED lights up and the buzzer sounds; pressing the
“ENTER” key causes the green “OK” LED to light up for correct procedures, or the red “ERROR”
LED to light up in the case of incorrect settings.
INSTRUCTIONS FOR USE
1. Connect the plug of the voltage transformer to the wall socket and the jack to its respective socket
positioned on the right face of the safe (see pic. 3).
2. Fit the 4 x 1.5-volt batteries (only alkaline batteries must be used) in its plastic seating on the
back of the internal lock (see Pic. 2) and completely remove (without screwing it back on) the
black screw marked with a special yellow label, which blocks the magnet.
3.
Test for opening using the service code “1111” (with door open and bolts pulled out):
Key in the service code “1111” and press “ENTER”. The green “OK” LED lights up for about five
seconds.
Within this time, with the green LED ON, turn the knob clockwise to retract the bolts.
If the combination is incorrect, the red “ERROR” LED will light up and the buzzer will sound.
After three attempts with incorrect codes, the keyboard will be disabled for one minute and this
time will be indicated by the red “ERROR” LED flashing. After this time, renewed readiness for
operation will be indicated by the green “OK” LED lighting up and a beep
STORING THE PERSONAL CODE AND SET TIME - DELAY
The procedure for storing the new code must be carried out with the door open and the bolts
pulled out.
Press the programming button (see Pic. 2) near the top of the back of the door once; the button
is marked with a yellow “PROGRAMMING” label
The green “CODE” LED switches on with a steady light and stays on for 10 seconds.
Within 10 seconds, start keying in your new personal code (min. 4 – max. 10 digits) and press
“ENTER”.
Key in your new code set again and press “ENTER” to confirm.
If the procedure has been carried out correctly, a long sound with a number of tones is emitted,
thus indicating that your code has been stored.
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Technomax Trony GTR-6P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Technomax Trony GTR-6P in the language / languages: English as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Technomax Trony GTR-6P

Technomax Trony GTR-6P User Manual - Dutch - 2 pages

Technomax Trony GTR-6P User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info