656211
18
Zoom out
Zoom in
Previous page
1/18
Next page
35
As Needed
Model
Impedance Meter
Main Unit
Laser
(for positioning)
Display
Settings
Measuring method
Measuring frequency
Measuring current
Electrode material
Measuring site
Measuring range
Power source
Measuring method
Measuring range
Battery
Power source
Light emitter
Laser wavelength
Laser output
Beam size
Classification
Estimated waist circumference
Trunk % fat
Visceral fat level
Trunk % fat determination
Visceral fat level determination
AB-140
4 electrode format
6.25kHz, 50kHz
500 µA
Stainless steel
Abdomen (at navel)
5 – 100
DC 6V/4 LR03 alkaline batteries (included)
Near infrared reflectance
20 – 48cm
(correlates to estimated waist circumference of 50 – 130cm)
Nickel-hydrogen rechargeable batteries; output DC 7.2V, 1mAh
AC adapter
Input: 100 – 240V
Output: 12V, 2A
Plug: centre minus
Visible light semiconductor laser
Wavelength: 650 nm (red light)
Max. 1mW
At a distance of 200mm: minimum line length
200mm; light width max. 2mm
Point ± 5mm from the centre (point is approx. Ø 1.5).
Class 2M
50 -130cm (increment: 1cm)
Increment: 0.1% (5.0 – 75%)
For
subjects
18 years
and over
1.0 – 59.0 levels (increment: 0.5 level)
Low – high (with bar indicator)
6 levels from average – excessive (with bar indicator)
Male / Female
Total Weight
External interface
Main unit: approx 2.6kg; Impedance meter: approx. 0.5kg
RS232C output (D sub 9 pin connector, female)
Usage temp. range -5 – +35ºC
Product Specifications
Temperature range for storage -10 – + 50ºC
is displayed.
•There is insufficient charge left in the main unit battery.
Recharge immediately.
Check the AC adapter connection.
Nothing is displayed when
the power is turned on.
The Charging LED does
not light up even when
charging has commenced.
Display
34
As Needed
Troubleshooting
Problem Try This
Please try the following prior to arranging repairs.
Measu
ring
Impedance meter error.
Buzzer does not sound,
or or is
displayed.
Store the impedance meter in the main unit to reset the
impedance meter status.
Ensure the abdomen is sufficiently wet (shave
abdominal hair if thick).
Check remaining impedance meter battery level (ensure
Power LED is on).
Impedance meter Power
LED does not come on.
Move the impedance meter switch hanger.
Replace batteries.
Communication error.
is displayed after the
buzzer sounds.
Place the impedance meter directly underneath the main
unit..
Do not move the equipment during data communication.
Ensure that the infrared ray transmitter and receiver are
clean. To clean, wipe with a soft cloth.
Ensure that nothing is covering the infrared transmitter
and receiver during transmission.
The waist circumference
displayed is too large or
too small.
Ensure that no clothes or other obstacles are within a
10cm area centred on the navel when measuring.
Ensure that the abdomen is not in contact with the
distance sensors during waist measuring.
Ensure that the distance sensors are clear of dirt or
moisture. Remove any dirt or moisture with a soft, dry cloth.
Calibrate.
•Check the waist size of the subject.
Calibrate.
Ensure the subject does not move while measuring the
waist.
Ensure no obstacles are between the distance sensors
when calibrating.
•Re-calibrate.
or is displayed
after calibration.
or is displayed
after waist measurement
is completed.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tanita AB-140 ViScan - Abdominal Fat Analyser at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tanita AB-140 ViScan - Abdominal Fat Analyser in the language / languages: English as an attachment in your email.

The manual is 2,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info