545179
3
Zoom out
Zoom in
Previous page
1/4
Next page
MODEL1210N
MODE CAL TARE ON/OFF
max.100ct・d=0.01ct0.64ozt・d=0.0001ozt308gr・d=0.05gr20g・d=0.002g
MODEL1210N
MODE CAL TARE ON/OFF
max.100ct・d=0.01ct0.64ozt・d=0.0001ozt308gr・d=0.05gr20g・d=0.002g
MODEL1210N
MODE CAL TARE ON/OFF
max.100ct・d=0.01ct0.64ozt・d=0.0001ozt308gr・d=0.05gr20g・d=0.002g
MODEL1210N
MODE CAL TARE ON/OFF
max.100ct・d=0.01ct0.64ozt・d=0.0001ozt308gr・d=0.05gr20g・d=0.002g
MODEL1210N
MODE CAL TARE ON/OFF
GB
USA
GB
USA
IMPORTANT
1. Use in location where there is little vibration.
2. If the change in temperature exceeds 5¡C (10¡F), wait at least 30 minutes before use.
3. Use on a hard flat surface.
4. Keep the cover closed when weighing.
5. Do not dismantle.
6. Clean using mild detergent. Chemicals should not be used.
Cover
Weighing tray
LCD display
Key buttons
Test weight
Lock release button
Gem cup
Lo battery mark
Stable mark
Minus sign
Calibration mark
Weighing modes
ON/OFF button
TARE button
CALIBRATION button
MODE button
⑰AC adaptor inlet
WEIGHING
CALIBRATING
1. Turn on the scale, and press the CAL button.
2. The display shows CALIb and then will flash CALIb .
3. Place the included test weight on the weighing tray. The scale will calibrate automatically.
4. The following messages will appear one after another;
CALIb End 20.000g
5. Calibration is completed. Remove the test weight.
Calibration is not completed when showing Err . Repeat calibration procedure.
PROGRAMMING AUTO POWER OFF
Default setting is 10 minutes.
The auto power off time can be programmed between 0 (=no auto power off) to 60
minutes by 10 minutes according to preference.
Press MODE button and ON/OFF button simultaneously when the unit is turned off.
The unit will then show the current setting.
1. Press TARE button to increase the length (the figure goes up by 10 minutes) and press
CAL button to decrease.
2. Press MODE button to set.
TECHNICAL SPECIFICATIONS
BEFORE USE
(Fig.1) (Fig.2)
◆Whenusingwithbatteries.
1.Pressthelockreleasebutton(Fig.1).
2.Removethebatterycoverandinsert4sizeAAA(LR03)batteriesasshowninFig.2.
3.Replacethebatterycover.
◆WhenusingwithACadaptor.
1.DonotuseanyACadaptorexceptthosewiththefollowingspecification.
NAMES OF PARTS
①
② ⑦
③
④ ⑤
⑥
⑧
⑨
⑩
⑪
⑫ ⑬
⑰
⑭⑮⑯
2.TouseACadaptor,puttheDCjackintotheinletasinthe⑰above.
Before measuring, we recommend you to carry out a calibration. ( see
"CALIBRATING")
1. Press the lock release button to open the cover (Fig.3).
2. Press the ON/OFF button to turn on the scale. The display will flash,
and when the display shows "0." and Stable mark, the scale is ready for
use.
3. Place the object to be weighed on the tray.
*If using the gem cup, remove the tray.
4. The object’s weight will be displayed.
5. In order to subtract the weight of the vessel or container, press the TARE button. "0." will
appear on the display, and when an object is placed on the scale, the weight of that object
only will be displayed.
6. In order to change the units of measurement, press the MODE button.
The units will change in the following order: g ct ozt grain
7. When you have finished weighing, press the ON/OFF button to turn off. The scale will turn
off automatically after ten minutes of inactivity.
8. When not in use, close the cover and push back until it locks.
*If you used the gem cup, remove it and put the weighing tray back in place.
"EEEEE" :Over Load. The object being weighed exceeds the maximum weight.
(Fig. 3)
Test weight
Capacity
Graduation
Power
Power Consumption
20g
20g / 100ct / 0.64ozt / 308gr
0.002g / 0.01ct / 0.0001ozt / 0.05gr
DC6V AAA(LR03) × 4 (included)
AC adaptor (DC6V 200m A) (WhenusingwithACadaptor.)
12mA (max.)
*Not legal for trade.
OnlyuseanACadaptorwithaCEmarking.
Push
Open
Push +
−
+
−
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tanita 1210N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tanita 1210N in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info