18. Emission Control System
18-8
Positive Crankcase Ventilation System (P.C.V.)
1. Construction
2. Principle of operation:
y Install a separated chamber on cylinder head, and suck the blow-by gas to the fuel vapor separator
by engine vacuum.
y Drill a hole in the air cleaner and install a vapor separator, so that blow-by from crankcase will flow
through a cylinder check valve and then separated by the separator.
y The separated vapor will be sucked into combustion chamber by engine negative pressure to be
burned again instead of discharging into atmosphere. Drain liquidized fuel in the drain pipe
periodically.
3. Service Methods
Visual check:
y Remove drain plug to drain the fuel when fuel level on the drain pipe reaches 80 % full.
y Check connecting hose for damage and looseness.
Cylinder
head
Carburetor
Flesh air
Exhaust pipe
Air filter
Fuel vapor separator
Crankcase
Blow-by pipe
Piston
Flesh air
Mixture gas
Blow-by
Engine oil
To this chapter contents
223


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sym Joymax 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sym Joymax 250 in the language / languages: English as an attachment in your email.

The manual is 7,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sym Joymax 250

Sym Joymax 250 User Manual - English - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info