Safety warnings
Disconnect the power supply before attempting any work on the unit!
During installation, the electrical wiring you are connecting must be dead. Therefore, switch OFF the
power first and use a voltage tester to check that the power supply is disconnected.
Installing these lights involves work on the mains voltage supply; this work must therefore be carried
out professionally in accordance with national wiring regulations and electrical operating conditions
(
D
- VDE 0100,
A
-ÖVE/ÖNORM E 8001-1,
-SEV 1000)
Do not install the unit on normally flammable surfaces.
Suitable for outdoor and indoor use.
LED floodlights are only intended for wall mounting and not for ceiling mounting.
The floodlight housing heats up while it is switched ON. Only adjust the angle of the LED head once it
has cooled down.
Only use genuine replacement parts.
Do not dismantle the unit yourself. It must only be repaired by a specialist workshop.
Do not look directly at the LED light close up or for any length of time (> 5 min.). This could
lead to damage of the retina.
Installation advice
The mains supply lead is a 3-core cable.
L = phase conductor (usually black or brown )
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Important: Getting the cable connections crossed will produce a short circuit in the unit or in your fuse
box. In this case, you must identify the individual cables and re-connect them. A mains switch for switching
the light ON and OFF can be installed in the mains lead.
Concealed wiring / surface wiring
Underneath the mounting plate you will find two lugs for surface wiring. Break off one of the two lugs. Use
the sealing plug to close off the cable opening in the mounting plate. Pierce the sealing plug and feed the
cable through. Once the cable has been pushed through, you can screw the mounting plate to the mount-
ing surface and complete the connection.
Troubleshooting (Cause Remedy)
No voltage / Fuse faulty, not switched ON, break in wiring New fuse, turn ON mains power switch, check
wiring with voltage tester. Short circuit Check connections.
Declaration of Conformity
This product complies with:
Low Voltage Directive 2006/95/EC / EMC Directive 2004/108/EC / RoHS Directive 2011/65/EC /
WEEE Directive 2012/19/EC.
Functional Warranty
This STEINEL product has been manufactured with utmost care, tested for proper operation and safety and
then subjected to random sample inspection. STEINEL guarantees that it is in perfect condition and proper
working order. The warranty period is 36 months and starts on the date of sale to the consumer. We will
remedy defects caused by material flaws or manufacturing faults. The warranty will be met by repair or
replacement at our own discretion. The warranty does not cover damage to wear parts, nor does it cover
damage or defects caused by improper treatment, maintenance or the use on non-genuine parts. Further
consequential damage to other objects is excluded. Claims under the warranty will only be accepted if the
unit is sent fully assembled and well-packed with a brief description of the fault, a receipt or invoice (date
of purchase and dealer's stamp) to the appropriate Service Centre.
Service:
Please ask your nearest service centre how to proceed for repairing faults not covered
by the warranty or occurring after the warranty expires.
ENGLISH
GB
321
110030973 10/2013_E
XLED-SL 10
XLED-SL 25
Information
H CZ SK PL RO SLO HR EST LT LV RUS BG
D GB F NL I E P S DK FI N GR TR
Projected floodlight area:
XLed-SL 10: 250 cm
2
+ 103.36 cm
2
XLed-SL 25: 420 cm
2
+ 103.36 cm
2
1 2
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel XLED-SL 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel XLED-SL 10 in the language / languages: All languages as an attachment in your email.

The manual is 13,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info