720837
3
Zoom out
Zoom in
Previous page
1/128
Next page
3
NEVER intentionally short any battery
terminals.
DO NOT attempt to charge alkaline
batteries.
DO NOT dispose of batteries in re.
ALWAYS remove the battery if storing the
unit for over a month.
DO NOT dispose of this product with
household waste.
ALWAYS check local codes and properly
dispose of used batteries.
PLEASE RECYCLE in line with local
provisions for the collection and disposal of
electrical and electronic waste.
WARNING:
Carefully read the User Safety and
Operating Instructions before
using this product. The person responsible
for the instrument must ensure that all
users understand and adhere to these
instructions.
WARNING:
The following labels are placed on the laser
tool to inform you of the laser class for your
convenience and safety.
OPERATING INSTRUCTIONS
BATTERY
Open the battery door on the handle of unit
and connect 2 AAA (1.5 V) batteries, ensuring
polarity is correct per the indication on the
inside of case. Replace battery door. It is
recommended to replace the batteries with
new batteries when battery indicator shows
OFF
SET
º
C/
º
F
SCAN
°C
°F
REF
HIGH
NORMAL
LOW
3cm@24cm
2cm@16cm
1cm@8cm
Distance to spot size = 8:1
Distance
.
USAGE
1. Point the IR Thermometer at the object
to be measured, pull and hold the
trigger. When the IR thermometer is in
measurement mode the LCD backlight
will illuminate and the laser will be on, the
measurement indicator “SCAN” icon will
also be displayed on the LCD.
When the trigger is released 3 audible
beeps will sound and the laser will shut off;
the last temperature reading will remain
on the LCD. After 15 seconds the LCD
backlight will turn off and after 1 minute the
IR Thermometer will turn off.
2. When the IR Thermometer is in the “ON”
state (trigger is not pulled), pressing the
OFF
SET
º
C/
º
F
SCAN
°C
°F
REF
HIGH
NORMAL
LOW
3cm@24cm
2cm@16cm
1cm@8cm
Distance to spot size = 8:1
Distance
button will select the desired unit of
measure: C° or F°.
3. When the IR Thermometer is in the “ON”
state (trigger is not pulled), pressing and
holding the
button for about 3 seconds
will turn the unit off.
4. When the IR Thermometer is in the
measurement mode (trigger is pulled and
held), pressing the
OFF
SET
º
C/
º
F
SCAN
°C
°F
REF
HIGH
NORMAL
LOW
3cm@24cm
2cm@16cm
1cm@8cm
Distance to spot size = 8:1
Distance
button will set the
reference temperature.
5. Press the
button to select the desired
temperature threshold (0.5°C/1°F, 3°C/5°F,
or 5.5°C/10°F). The
OFF
SET
º
C/
º
F
SCAN
°C
°F
REF
HIGH
NORMAL
LOW
3cm@24cm
2cm@16cm
1cm@8cm
Distance to spot size = 8:1
Distance
icon indicates your
current setting.
To disable the threshold feature, press the
OFF
SET
º
C/
º
F
SCAN
°C
°F
REF
HIGH
NORMAL
LOW
3cm@24cm
2cm@16cm
1cm@8cm
Distance to spot size = 8:1
Distance
button until the
OFF
SET
º
C/
º
F
SCAN
°C
°F
REF
HIGH
NORMAL
LOW
3cm@24cm
2cm@16cm
1cm@8cm
Distance to spot size = 8:1
Distance
icon is over the
“OFF” mark.
6. Once a reference temperature and
temperature threshold are set the unit
can be used to scan areas for changes in
temperature. While in measurement mode
the backlight will be green and “NORMAL”
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stanley STHT0-77365 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stanley STHT0-77365 in the language / languages: All languages as an attachment in your email.

The manual is 18,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info