8.1Set current time
For a concrete function of the installation, it is required that the
current time is set when it is commissioned or after several days
of power failure (about 96 hours).
With the Plus / Minus buttons ( / ) the value of the
current cursor position is being modified.
With the button Enter ( ) you go to the following set value or
you will quit the menu on the last position.
8.2Menu "01 Temperatures"
In this menu, the current temperature values are being displayed.
First, an overview of the following items is displayed:
outside temperature (desired flow temperature) and actual flow
temperature.
By pressing the button, any of these values and the correction
value of the optionally pluggable remote controller RT21 may be
displayed individually with clear text.
8.3 Menu "02 Operating times"
In this place, the heating circulation daily operation ranges are
set which are performed either in daily programs (same every
day) or in weekly programs (individual settings every day). Up to
3 daily operating heating circuit ranges may be selected for every
day. For any daily operating range you may determine if it shall
take place with or without additional comfort peaking.
Outside the daily operating times, the heating will work in the
lowered overnight operation.
The daily operating hours may be selected from 0.00 to 24.00h
every day. If the second or third daily operating range is not
required, the starting time is to be set to 24:00h in order that no
further daily operation will take place.
Daily correction, comfort peaking as well as the overnight lowering
are described in detail under 8.4 Menu "03 Settings".
8.4Menu "03 Settings"
In this menu, the settings are performed for the regulating
functions and therewith for the required temperature range.
S/W day 18°C (setting range 10...30°C)
Select the outdoor temperature at which the summer/winter
switching shall take place during the heating circuit operation.
Summer operation: As soon as the selected temperature value
is exceeded, the mixer will shut down completely and the heating
circuit pump will switch off. Winter operation: As soon as the
temperature remains under the set value, the heating operation
will be restarted.
S/W night 12°C (setting range 10...30°C)
refer to S/W day, but it is valid for the heating circuit overnight
operating time.
VL>HZK OFF 15°C (setting range 7...30°C)
If the desired flow temperature remains under the value which is
set here, the mixer will shut down and the heating pump will
switch off.
To be followed 03 Settings on page 4
03 Settings Selecting or
confirming with
02 Operating times Selecting or
confirming with
05 Clock setting 13:59 16.02.05
7. Short overview of the menu control
The main menu of the HR3 consists of the following menu items
described in short. The required menu is selected with the Plus
or Minus button and it is confirmed with the Enter button.
Display menu:
- temperature values
- desired course
Setting menu:
- weekly program
- daily program
Setting menu for:
- desired values
- summer /winter
switching
Setting menu for:
- Automatic operation
- contin. day operation
- contin. night operation
- manual operation
- setting value operation
- Off
Setting menu for:
- time
- date
Special function:
- voice selection
- mixer running time
- antifreeze function
- manual offset
- probe 3 (e.g. RT21)
Menu interlocking:
Interlocking function
against unvoluntary
misadjusting in the
menus:
- 02 settings
- 03 operating mode
- 04 times
- 05 special function
Administration of
standard values
(presettings and user
settings)
Display of the service
values
01 Temperatures
02 Running times
03 Settings
04 Operational mode
05 Clock setting
06 Special function
07 Menu interlocking
08 Standard values
09 Service values
3
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel HR3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel HR3 in the language / languages: English as an attachment in your email.

The manual is 0.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel HR3

Sorel HR3 User Manual - German - 6 pages

Sorel HR3 User Manual - French - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info