12 Copyright © 2008 Somfy SAS. All rights reserved.
EN
Elixo 500 24 V
Clearing all remote controls
Press the PROG button on the motorisation control unit for more than 7 seconds. The indicator light ashes to indicate that all
remote controls have been cleared.
Clearing all settings
Press OK twice to access the menus.[1]
Use the + and - buttons to access the [2]
dEFAULt menu.
Press OK to clear all settings.[3]
The Elixo motorisation has been reset and returns to its original con guration (factory default
settings).
Before using the motorisation, carry out a new self-learning procedure (see pg. 8).
Meaning of messages displayed on the screen
Before accessing the menu list, the control unit screen displays the following information:
Somfy,
Control unit software version,
Number of cycles carried out (expressed in hundreds; during the rst 100 manoeuvres the screen displays 0000).
Whilst the motorisation is in use, messages are displayed to show the system’s status.
In the event of incorrect operation, a message will be permanently displayed to show the device to be checked. If the problem is
not corrected or if it persists, please contact Somfy technical assistance.
Message Meaning Permanent display
OK Self-learning successful
KO Self-learning unsuccessful
Awaiting input of a value or function
End Exit programming mode
SuC Closing end limit activated
SuO Opening end limit activated
AMP Obstacle detected
PED Pedestrian entry activated Check that the device controlling pedestrian entry is operating correctly (keyswitch,
wired keypad, etc.)
STRT START entry activated Check that the device controlling the START entry is operating correctly.
STOP STOP entry activated Check that the device controlling the STOP entry is operating correctly.
PHOT PHOT entry activated Check that nothing is obstructing the photoelectric cells.
Check that the photoelectric cells are not dirty (see guide for the cells).
CLOSE CLOSE entry activated Check that the device controlling the CLOSE entry is operating correctly.
OPEN OPEN entry activated Check that the device controlling the OPEN entry is operating correctly.
SWO Opening end limit entry activated Faulty electro-magnetic detection system. Replace it.
SWC Closing end limit entry activated Faulty electromagnetic detection system. Replace it.
TH Software thermal protection activated Wait until the message disappears before continuing to use the motorisation.
OK
OK
-
+
OK
OK
+ -
CLEARING THE REMOTE CONTROLS AND ALL SETTINGS
DIAGNOSTICS
Menu [Display] Value By
default
Comments
START-CLOSE selection
[StArt - cLoSE]
ON: the input between
terminals 21 and 22 operates
as CLOSE.
OFF CLOSE: the device connected between terminals 21 and 22 only
enables the gate to be closed.
OFF: the input between
terminals 21 and 22
operates as START.
START: the device connected between terminals 21 and 22
enables the motorisation to operate in sequential mode.
Pedestrian opening
[PEdEStrIAn]
ON: Activates the pedestrian
opening.
OFF: Deactivates the
pedestrian opening.
OFF Operation of the pedestrian opening: pressing the button brie y
opens the gate partially and pressing and holding the button opens
the gate fully.
Fixed opening time: 7 seconds.
Preset [dEFAULt]: to reset the motor (factory default settings).
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Somfy Elixo 500 24 V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Somfy Elixo 500 24 V in the language / languages: English as an attachment in your email.

The manual is 3,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info