535678
9
Zoom out
Zoom in
Previous page
1/11
Next page
17
Putting into operation
Finding the ideal location for your humidifier:
A slightly heightened place, approx. 30 to
50 cm above the floor.
Please note that:
Do not place the device directly on the floor
or next to heating.
The vapour outlet must not be pointed
directly at plants or other objects.
Make sure that no foreign objects are in the
water tank.
Fill the tank with clean, cold water from the
tap (water no hotter than 40°C). Close the cap
of the water tank properly. Do not add any
conditioners to the water.
Soak the cartridge in water for a few hours
before using it.
The demineralization cartridge should be
replaced every 2–3 months.
Place the water tank on the base and insert
the vapour outlet.
Insert the plug into the socket and switch on
the appliance using the on/off switch.
About 10 to 15 minutes after having been
switched on the device will reach is full power.
Attention!
The water tank is equipped with a
demineralization cartridge. This cartridge has
to be replaced every 2–3 months.
If the water is very hard, it may be necessary
to replace the cartridge earlier.
We do not recommend the use of this
Ultrasonic Nebulizer if your water is harder
than 25 fH!
White dust around the device is a sure sign
that the cartridge is empty.
If white precipitate still forms around the device
after a new cartridge has been inserted, please
make sure that the water you are using is really
untreated. (no conditioner)
If the water flows through a decalcification
system in the building before it is used in the
humidifier, salt will precipitate around the
device.
Replacement of the demineralization
cartridge
Turn around the tank and open the turn-lock. The
demineralization cartridge is attached to the
inside of the cap. Unscrew the cartridge turning it
anti-clockwise and replace it with
a new one.
16
Dear Customer
Congratulations on your choice of the
SOLIS Ultrasonic Nebulizer!
The physical well-being of people and animals is
influenced by numerous factors, one of which is
the right humidity level of room air. During heating
periods, cold and dry outside air flows into rooms
through the windows, where its temperature rises.
This leads to a massive drop in relative room
air humidity, creating an unfavourable climate for
people, animals and plants. Your well-being
suffers, you become more vunnerable to cold an
flu germs.
Humidification by Ultrasonics:
A highly efficient technology allowing controlled
humidification. High frequency oscillations
transform the water into a microfine mist which is
then passed into the room where it immediately
evaporates.
Ultrasonic humidifiers have a low power
consumption. A replaceable demineralisation
cartridge cleans the water from minerals and
other waterborne residues thus providing a
pure mist. Ultrasonic humidifiers are equipped
with an integrated hygrostat and output control.
General Information
A comfortable atmosphere indoors is reached with
a relative humidity level between 40 and 60%.
Your humidifier controls automatically the
humidity level according to desired setting. If the
air is too dry, the humidifier will automatically
switch on. As soon as the desired humidity level is
reached, it will switch off.
Safety instructions:
Read the operating instructions carefully before
using the humidifier and keep them for later
reference.
Connect the unit only to alternating current
with voltage according to the rating label.
Only use the humidifier indoors and within the
specified technical data. If used for a purpose
for which it is not intended it could cause
serious danger to health and life.
Children cannot recognise the hazards
associated with the usage of electrical
appliances. For this reason, always supervise
children when they are near the humidifier.
Persons who are not familiar with the operating
instructions, as well as children and persons
under the influence of medication, alcohol, or
drugs are not permitted to operate the
appliance, or are only permitted to operate it
under supervision.
Never use the appliance if there is any damage
to the appliance or cable, after malfunction,
after the appliance has been dropped or
damaged in any other way.
Only operate the humidifier when it is
completely assembled.
Repairs of electrical appliances are only to be
made by qualified service engineers. Improper
repair work can cause considerable danger to
the user.
Disconnect the appliance from the mains power
before filling/emptying the water tank, before
cleaning/ maintenance, assembling/
dismantling of individual parts and before
moving the appliance.
Place the humidifier on a dry, level surface. Do
not place the device directly on the floor or next
to heating.
Do not pour water into the vapour outlet of the
humidifier.
Do not put any additives in the water (e.g.
fragrances, essential oils, water fresheners,
etc.)
Do not submerse the main body in water or
other liquids.
BDA_Ultrasonic.qxd 7.7.2005 17:14 Uhr Seite 16
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Solis Ultrasonic Type 715 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Solis Ultrasonic Type 715 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info