11.8 Technical information
Hob model See rating plate
Electrical connections 220-240V~ 50/60Hz / 380-415V 2N~ 50/60Hz
HOB RATING I
Maximum power See rating plate
11.9 The rating plate
Make sure that the voltage and capacity of the power line conform to the data shown on the plate located
under the casing. Do not remove this plate for any reason.
11.10 Electrical connection
The electrical connection of the hob must be installed by an authorised technician.
The applicable legislation and rules for connection to the local electricity supplier must be followed.
Detach the appliance from the power supply when you wish to repair it.
The earthing wire must be longer than the current conduction wires so that, if the plug is torn off the
power cable, it is the last to be detached.
Surplus parts of the cable must be taken out of the installation area under the appliance.
To make the connection, the control cover underneath the
device must be opened to reach the terminal board. Once
the connection has been made, the cover must be fixed
back in place and the cable must be locked using a traction-
resistant clamp.
The connection cable must correspond to type H05 V2V2-F
as a minimum.
If the appliance connection cable is damaged, it must be
replaced by the manufacturer, their Technical Support
Service or a qualified technician to avoid any danger.
When the appliance has been installed, it must be protected
from accidental contact with the electric cables.
Warning! The electronic controls could be damaged beyond repair if the connection is not
professionally carried out.
IT IS OBLIGATORY FOR ALL ELECTRICAL EQUIPMENT TO BE EARTHED ACCORDING TO THE
METHODS LAID DOWN BY SAFETY REGULATIONS.
WHERE THE APPLIANCE IS CONNECTED TO THE POWER GRID VIA A PLUG AND SOCKET,
BOTH OF THESE MUST BE OF THE SAME TYPE AND CONNECTED TO THE POWER CABLE IN
ACCORDANCE WITH THE APPLICABLE REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE IS INSTALLED.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION, CARRY OUT A QUICK TEST ON THE APPLIANCE
FOLLOWING THE INSTRUCTIONS PROVIDED EARLIER IN THIS MANUAL. IF IT DOES NOT
FUNCTION CORRECTLY, AFTER HAVING ENSURED THAT THE INSTRUCTIONS HAVE BEEN
PROPERLY FOLLOWED, DISCONNECT THE APPLIANCE FROM THE POWER SUPPLY AND CALL
THE NEAREST TECHNICAL SUPPORT CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
RUN THE POWER CABLE UNDER THE UNIT, TAKING CARE THAT IT DOES NOT COME INTO
CONTACT WITH THE BOTTOM OF THE CASING OF THE HOB OR THE OVEN BENEATH IT IF
THERE IS ONE.
IF A PLUG AND SOCKET CONNECTION IS USED, CHECK THAT THEY ARE THE SAME TYPE. DO
NOT USE ANY TYPE OF ADAPTOR OR DIVERTER AS THESE MAY CAUSE OVERHEATING OR
BURNS.
WHERE A FIXED CONNECTION IS IN USE, A MULTIPOLAR CUT-OUT DEVICE MUST BE
INSTALLED ON THE SUPPLY CABLE WITH A CONTACT OPENING DISTANCE EQUAL OR
GREATER THAN 3 MM, LOCATED IN A READILY REACHABLE POSITION NEAR THE APPLIANCE.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg se644id 1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg se644id 1 in the language / languages: English as an attachment in your email.

The manual is 0,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg se644id 1

Smeg se644id 1 User Manual - German - 25 pages

Smeg se644id 1 User Manual - Dutch - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info