109380
5
Zoom out
Zoom in
Previous page
1/6
Next page
8
outlet in conformity with local standards in force.
Where an electrical plug is not provided (for direct
connection to electrical network) place a standards approved
bipolar switch with an aperture distance of not less than
3mm (accessible) from the contacts.
Mounting the Hood
The diameter of the ventilation duct must be the same as
the that of the flange mounted on the ventilation hole on the
hood.
To mount the hood proceed as follows:
Position the drilling template inside the left cupboard
on the right hand side with the arrow point towards
the back on the cupboard (Fig. 8)
Drill the holes marked on the template (Fig. 8)
Repeat the procedure for the right hand cupboard
If the sides of the cupboards are 18 mm thick, insert
4 spacers M on the sides of the hood (Fig. 9)
Fix the hood to the cupboard using four screws N
(Fig. 9).
Adjusting the Pull-Out Drawer
The hood can be installed beneath cabinets with varying
depths. Adjustments for opening and closing the drawer
can be made based on your specific needs.
To adjust the drawer, remove the ventilation grates by
loosening the O screws and adjusting the P brackets. Then
retighten the O screws (Fig. 10).
Using the hood
The hood is provided with several speeds.
For the best performance, we recommend using the low
speeds in normal conditions and the high speeds when
strong odour and vapour concentrations are present.
We recommend starting the hood a few minutes before
cooking and keeping it running for at least 15 minutes until
all the odours have been eliminated.
Maintenance
Caution! Before performing any maintenance,
disconnect the hood from the electrical supply.
Grease Filter
The grease filter serves to trap grease particles by
suspending them.
1. Synthetic Filter (thickness: 10-15 mm): wash the
filter in warm water and a biodegradable detergent
once a month. Let dry without wringing. Replace after
the filter has been washed 5 or 6 times.
2. Thin Synthetic Filter (approximately 1 mm thick):
replace when the coloring from the top is visible on the
bottom part.
3. Thin Synthetic Filter (approximately 1 mm thick -
without saturation indicator) replace every two months.
4. Metal Filter: unlimited life; wash every month in
warm soapy water, or, if possible, in the dishwasher
(60°C). Let dry before reinstalling it.
Removing the Grease Filters (for models wtih grease
filter support grates)
To remove the dirty grease filter, proceed as follows:
a. Remove the pull-out drawer completely and open the
ventilation grates that support the grease filters.
b. Remove the Q fasteners for the grease filter and
remove it (Fig. 11.1). If special metal filters have been
installed, press on the plastic springs R to unhook them
(Fig. 11.2).
c. When washing or replacing the grease filter, wash the
grate as well with warm soapy water.
d. Remount the new filter or the old one after it has dried
thoroughly.
Charcoal Filter
The charcoal filter serves to eliminate odours that form
during the cooking process. Under normal use conditions,
the filter should be replaced every 4 months. It can be
ordered from the retailer. The charcoal filter must never be
washed.
To remove the charcoal filter, proceed as follows:
a. Remove the pull-out drawer.
b. Remove the grease filters and open the light cover
support (or the greas filter support grate).
c. Reverse the procedure described in item 1) or 2),
depending on the version, of the “Air recirculation”
paragraph.
Replacing the Lamp
a. Remove the pull-out drawer.
b. Open the light cover support or the back grease filter
support grate.
c. Always replace burnt-out lamps, according to what is
provided for your appliance, with olive-shaped max.
40 Watt (E 14) bulbs, or neon-lamp 14 Watt max., or
PL lamp 11 Watt (one PL lamp appliance) or PL 9 Watt
(two PL lamp appliance).
d. Close the light cover support or the back grease filter
support grate.
e. Before calling for customer service because the
lighting system does not work, make sure that the
lamps are screwed in tightly.
Cleaning
To clean the outside of the hood use a cloth moistened with
denatured alcohol or neutral liquid detergents. Never use
products containing abrasives.
Attention
Failure to observe the instructions for cleaning the appliance
and changing and cleaning the filters may cause fires.
Therefore, we recommend observing these instructions.
GB
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg KSET 900 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg KSET 900 in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg KSET 900

Smeg KSET 900 User Manual - German, Dutch - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info