Operating Instructions
en
RDG100KN
RDG160KN
RDG165KN
RDG100KN / RDG160KN / RDG165KN the room thermostat with KNX communications that allows
you to set the ideal room temperature you want. The thermostat provides Comfort, Economy and
Protection mode.
In addition it can operate in Auto timer mode according to a schedule via KNX bus.
The fan operates either in Automatic mode or at the selected speed when using Manual mode.
You can either rely on the factory settings or make adjustments that suit your individual needs.
Humidity control is available on RDG165KN.
Main display Operating mode
Room temperature
Heating mode
Outdoor temperature
Electric heater active
Room temperature in degrees
Celsius
Cooling mode
Room temperature in degrees
Fahrenheit
Comfort mode
Humidity
Economy mode
Button lock active
Auto timer mode
Fault indicator *
Protection mode:
Protection against frost
Condensation in the room *
Humidity control active
Indicator for mode selection
Timer function active
Weekday 1 = Monday
7 = Sunday
Additional user info, e.g.
current time of day, or
rel. humidity
Fan mode
Escape (Cancel)
Automatic fan
Confirm (OK)
Manual fan:
Low Medium High
Operating mode button
Fan mode button
Rotary knob
* Needs to be configured by your HVAC installer
Changing the room temperature
Turn the rotary knob clockwise (+) to increase, or counterclockwise (-) to decrease
the current room temperature setpoint. The thermostat changes to Comfort
.
The setting range is from 5...40 °C; it can be limited by parameters P09 and P10.
(for parameter settings, see reverse side).
Adjusting the fan speed
Low Medium High
Press the right button repeatedly until the desired fan mode is reached.
In Automatic mode , the fan speed is automatically selected by the thermostat
depending on the setpoint and the actual room temperature.
RDG100KN: When the room temperature reaches the setpoint, the fan keeps
running at low speed (factory setting).
RDG16..KN: The fan stops (factory setting) or keeps running at low speed (P15).
In Manual mode, the fan operates independently and always runs at the speed
you set: low / medium / high.
Note:
If desired, you can change the fan mode selector option via P03: Auto / manual, Manual only, or
Manual including Protection mode.
Changing the operating mode of the thermostat
Press the operating mode button repeatedly until the symbol points to the operating
mode you desire.
1. Protection mode
In protection mode, the plant stops operating. However, if the room temperature
falls below 8 °C, heating is switched on to protect the room against frost.
RDG165KN: the thermostat switches to protection mode when the window
contact (local or on KNX) is active.
The setpoints for Protection mode can be changed by your HVAC installer if desired:
Changes made by installer: Frost protection: _________ ˚C Heat protection: __________˚C
2. Comfort mode
In Comfort mode, the thermostat maintains the room temperature on the setpoint
which can be adjusted with the rotary knob.
RDG165KN: the thermostat switches to Comfort mode when the presence detector
(local or on KNX) is active (room is occupied).
3. Auto Timer mode
In Auto Timer mode, the thermostat automatically switches over between Comfort
and Economy mode according to the schedule via KNX bus.
If no schedule via KNX is available, then Auto Timer is replaced by Comfort.
4. Economy mode
In Economy mode, the thermostat maintains the room temperature at a lower or
higher setpoint, thus saving energy and money.
The thermostat can be set to Economy mode either by pressing the operating
mode button if enabled (P02 = 2), or via an external signal (switch or KNX bus
command) such as window switch (RDG1..0KN), keycard or presence detector.
The Economy setpoints are factory-set to 15 °C for heating and 30 °C for cooling.
They can be adjusted via parameters P11 and P12 (for parameter settings, see
reverse side).
Important: These setpoints can be set to OFF; which means that the thermostat
is not active, i.e. no protective heating or cooling function. Risk of frost!
Changing from heating to cooling mode
The changeover from heating to cooling (or vice versa) is made
either automatically
by a changeover sensor, or a changeover switch, or a
remote changeover switch via KNX command.
or manually by pressing the operating mode button.
If the thermostat is configured for "heating only" or "Cooling only", changeover is
not available (see parameter P01)
To select cooling or heating manually (P01=2), press the operating mode button
until the
symbol points to the mode you desire.
With automatic changeover or continuous heating / cooling, symbols
indicate that the system currently heats or cools.
With manual changeover, symbols indicate that the system currently
operates in heating or cooling mode. Symbols
indicate that the system
currently heats or cools.
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens RDG160KN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens RDG160KN in the language / languages: English as an attachment in your email.

The manual is 0,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens RDG160KN

Siemens RDG160KN User Manual - German - 2 pages

Siemens RDG160KN User Manual - French - 3 pages

Siemens RDG160KN Installation Guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info