555888
4
Zoom out
Zoom in
Previous page
1/4
Next page
4/4 Operating Instructions CB1B1425en_01 / 2014-11-26 Siemens Building Technologies
Does symbol appear on the display?
Symbol
is displayed when the batteries are low.
Replace them with 2 new alkaline batteries type AAA.
Proceed as follows:
· Get 2 new alkaline batteries type AAA
· Remove the battery holder and then the batteries.
Insert the new batteries and, within 1.5 minutes,
replace the battery holder
· Ensure the exhausted batteries are disposed of
correctly, in compliance with environmental
requirements
Do you want to lock the keypad?
Mode Press and hold Mode for at least 7 seconds to
activate a button lock. Repeat to unlock.
The unit operates normally when the buttons
are locked, but changes cannot be made.
Receiver’s LED indication
State of receiver State of LED
Power up (or reset) The red and green LEDs flash
alternately for 5 seconds, then
change to constantly red.
Note: If the receiver was previ-
ously programmed, it shows
immediately constantly red.
Learning mode
Successful learning
mode
The red and green LEDs flash
alternatively.
If RCR100RF learning is
successful, the green LED will
flash for 10 minutes.
Signal ok and
output status
change
The green LED is constantly lit,
and if the output status
changes, the green LED flashes
for 3 seconds, then changes
back to constantly green.
Fail to receive
wireless data
If the RCR100RF fails to receive
wireless data, the red LED will
start to flash after 125 minutes.
If the RCR100RF signal is
recovered, it will return to the
previous LED state.
Do you want to change parameters?
+
Ok
Mode
If you want to change control parameters,
proceed as follows:
· Press + and simultaneously for 5
seconds
· Release the buttons and parameter
P01 is displayed on the bottom
segment
· Press + or to scroll to the parameter
that needs to be changed
· Press Ok to select the parameter
· Press + or to change the value
· Press Ok to confirm the changed value
· Press Mode to exit the parameters
without saving or wait for the program
to exit automatically
Parameter list
Parameter
no.
Description Setting range
(default)
P01 Time format 1 = 24:00 hours
(default)
2 = 12:00 am/pm
P02 Selection of °C or
°F
1 = °C (default)
2 = °F
P03 Standard
temperature display
1 = room temperature
(default)
2 = setpoint
P04 Temperature
sensor calibration
-3…3 °C
Step 0.5 °C
(-6…6 °F, step 1 °F)
Default: 0 °C
P06 Comfort setpoint
lock
0 = OFF (default)
1 = ON à locked
according to setting
in permanent
temperature setpoint
P08 Economy setpoint
lock
0 = OFF (default)
1 = ON à locked
according to setting
in permanent
temperature setpoint
P09 Buzzer 0 = OFF
1 = ON (default)
P10 Show frost
protection icon
0 = OFF (default)
1 = ON
P11 Time switch type for
Auto Timer
0 = individual days
(default)
1= all 7 days
2= 5-2 days
P12 Periodic pump run 0 = OFF (default)
1 = ON
P14 X1 external input 0 = no input (default)
1 = external sensor
2 = digital input
P15 Temperature
limitation
0 = OFF (default)
1 = ON
P16 Max. limitation
temperature for
floor heating
35…60 °C, step 1 °C
or
95…140 °F, step 1 °F
Default: 55 °C
P17 Window contact
features
0 = normally open
contact (default)
1 = normally closed
contact
P19 Sequential number
of room unit
0 = no display of
zone (RF off)
1 = zone number 1
(for standard RF)
(default)
6 = zone number 6
P20 RF learn 0 = OFF (default)
1 = ON
P21 Scanning rate for
the capacitive
buttons
Note: Shorter
scanning rate
means shorter
battery life
0.2 = 0.25 s
0.5 = 0.5 s
1.0 = 1.0 s (default)
1.5 = 1.5 s
P22 Reload factory
settings
0 = OFF (default)
1 = reload
P23 Software version
information
No adjustment
possible
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens RDE100.1RFS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens RDE100.1RFS in the language / languages: English as an attachment in your email.

The manual is 0,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens RDE100.1RFS

Siemens RDE100.1RFS User Manual - German - 3 pages

Siemens RDE100.1RFS User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info