1791
9
Zoom out
Zoom in
Previous page
1/13
Next page
9
Athen / IM-MEA EN / A31008-M1801-A601-1-UZ19 / Athen_Kombi.fm / 30.10.2008
Resetting the handset
You can reset any individual settings and changes
that you have made. Entries in the directory, the
calls list and the handset's registration on the base
station will be retained.
MENU ¢ Settings ¢ OK ¢ Handset ¢ OK
¢ Reset Handset ¢ OK
Cancel the reset with
a.
Base station settings
The base station settings are carried out using a
registered handset.
For details on how to set the system PIN for the
base station, and for how to select the ringtone
volume and melody on devices with answering
machines, see Menu tree, page 12.
Restoring the base station to the factory
settings
When the settings are restored all handsets are de-
registered. The individual settings are reset. Only
the date and time are retained.
MENU ¢ Settings ¢ OK ¢ Base ¢ OK
¢ Base Reset ¢ OK
If you have forgotten your system PIN you can reset
the base station to the original code 0000:
Disconnect the power cord from the base station.
Hold down the registration/paging key
÷ or ù
(page 1) on the base station while reconnecting
the power cable to the base station at the same
time. If your device has an answering machine you
will also hear a beep. The base station has now
been reset and the system PIN 0000 set.
Operating the base station on the PABX
The following settings are only necessary when
your PABX requires them, see the PABX user guide.
Changing the dialling mode
MENU ¢ 33911 ¢ The number for the set
dialling mode flashes: 0 = Touch tone dialling
(DTMF); 1 = Dial pulsing (DP)
¢ Enter number
¢OK.
Setting the flashing time
MENU ¢ IIO12 ¢ The number for the cur-
rent flashing time flashes
: 0 =80ms; 1 = 100 ms;
2 =120ms; 3 = 400 ms; 4 = 250 ms; 5 = 300 ms;
6 = 600 ms; 7 = 800 ms ¢ Enter number ¢ OK.
Changing pause after line seizure
You can set the length of the pause inserted
between pressing the talk key
c and sending the
phone number.
MENU ¢ IIO1O ¢ The number for the current
pause length flashes: 1 = 1 sec.; 2 = 3 sec.; 3 = 7 sec.
¢ Enter number ¢ OK.
Changing the pause after the recall key
MENU ¢ IIO14 ¢ The number for the current
pause length flashes: 1 = 800 ms; 2 = 1600 ms;
3 = 3200 ms ¢ Enter number ¢ OK.
Appendix
Entering special characters
Standard characters
Specifications
Recommended battery pack
(Valid at the time of going to press)
Nickel-metal-hydride (NiMH):
Handset A16: V30145-K1310-X383
Handset A26: V30145-K1310-X359, X402
The handset is supplied with the recommended
battery pack.
Base station power consumption
In standby mode: approx. 2W
During a call: approx. 3W
General specifications
1x 2x 3x 4x 5x 6x
1 Space 1 £ $ ¥ ¤
Q .,?!0+
P * / ( ) < =
#
Abc-->
123
123-->
abc
#@ \ &
DECT standard is supported
GAP standard is supported
Range up to 300 m outdoors,
up to 50 m in buildings
Base station power supply 230 V ~/50 Hz
Environmental conditions
in operation
+5 °C to +45 °C;
20% to 75% humidity
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens A265 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens A265 in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens A265

Siemens A265 User Manual - German - 13 pages

Siemens A265 User Manual - Dutch - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info