USAGE CAUTIONS
Ventilate the room periodically during use, especially if using gas appliances.
Be sure to turn the unit off and disconnect the power supply cord before performing any
maintenance or cleaning.
Do not splash or pour water directly onto the unit.
Water can cause electrical shock or equipment damage.
Drainage should be performed whenever moving the air conditioner. (See Page 17)
If any water remains in the tank, it may spill out while being moved.
To ensure proper drainage, the drainage hose must have no kinks or be on a different level
during dehumidification mode.
The drained water may spill out into the room.
The temperature around the drainage hose must not be below freezing point when used.
Drained water may freeze inside the hose, causing water inside the unit to overflow into the room.
Do not block the exhaust air outlet with obstacles.
Cooling performance may be reduced or stop completely.
Provide an earth leakage breaker in order to protect against electric shock in case of leak. Use
the current-activated, high-sensitivity, high-speed type breaker with a rated sensitivity current of be-
low 30 mA and an operating time of below 0.1 second.
NOTES ON OPERATION
Allow 3 minutes for the compressor to restart cooling.
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to
restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three
minutes for safety.
In the event of a power failure during use, allow 3 minutes before restarting the unit.
After power is reinstated, restart the air conditioner. If the power was off for less than three minutes,
be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within
three minutes, a protective device in the unit may cause the compressor to shut off. This protective
device will prevent cooling for about 5 minutes. Any previous settings will be canceled and the unit
will return to its initial settings.
Low temperature operation: Is your unit freezing up?
Freezing may occur when the unit is set close to 18°C in low ambient temperature conditions,
especially at night.
In these conditions, a further temperature drop may cause the unit to freeze.
Setting the unit to a higher temperature will prevent it from freezing.
Dehumidification mode increases room temperature.
The unit generates heat during dehumidification mode and the room temperature will rise. Warm air
will be blown out from the Exhaust air outlet, but this is normal and does not indicate a problem with
the unit.
This air conditioner blows the warm air generated by the unit outside the room via the ex-
haust hose while in cool mode.
Accordingly, the same amount of air as that blown out will enter the room from outside through any
openings into the room.
OPERATING CONDITIONS
The air conditioner must be operated within the temperature range indicated below.
IMPORTANT SAFETY INSTRUCTIONS
E-2
* Available for operation at condition of supply
voltage 220 V or over, not exceeding 240 V.
A built-in safety device may cut off operation if
the temperature exceeds these limits.
When cooling operation is performed at high
room temperature, the fan may run slightly
slowed
Mode Room temperature
COOL
upper limit *40°C
lower limit 18°C
DEHUMIDIFICATION
lower limit 15°C
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp CV-P09FR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp CV-P09FR in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sharp CV-P09FR

Sharp CV-P09FR User Manual - Dutch - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info