735544
13
Zoom out
Zoom in
Previous page
1/15
Next page
CO2 LEVELS AND GUIDELINES
The following are excerpts from
ANSI/ASHRAE addendum standard
62.1-2004:
Enforceable and/or regulatory levels:
OSHA -5000ppm
The Occupational Safety and Health
Administration
MAK -5000ppm or 10000ppm(1h)
German institution
Non-Enforced Guidelines and Reference
levels:
Canadian - 3500ppm (Long-term)
NIOSH-5000ppm or 30000ppm(15 min)
The U.S.National Institutes of Health
ACGIH-5000ppm or 30000ppm(15min)
The American Conference of Govern-
mental Industrial Hygienists (ACGIH)
NOTES :
TWA(Time Weighted Average) value
stands for the average carbon dioxide
level exposure during 8 hours(working
day) is 5000ppm/5 days.
STEL(Short-Term Exposure Limit)
value shows the last 15 minutes CO2
concentration is 30,000ppm.
ASHARE Standard 621989,Sec.6.1.3
:Comfort (odor) criteria are likely to be
satisfied if the ventilation rate is set so
that 1,000 ppm of CO2 is not exceeded.
12
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Senseair pSENSE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Senseair pSENSE in the language / languages: English as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info