735557
4
Zoom out
Zoom in
Previous page
1/4
Next page
Document
IMA0121
Rev
3
Page
4 (4)
Configuration jumper for OUT2 output
The output OUT2 can be used as a voltage or current output. The output is
configured by the jumper on top of the PCB. The configuration of the output can be
changed by moving the jumper to the desired position. The output has to be
reconfigured before the unit is powered up.
Figure 5. The upper part of the eSENSE II PCB seen from the back with the jumper in
voltage (default) and current position
Self-diagnostics
The system contains complete self-diagnostic procedures that are executed
automatically when the sensor is in operation. Sensors with display show a wrench if
an error is found. The wrench is shown during the first seconds after power up and if
the measuring range 2000 ppm is exceeded. The output OUT2 indicates the same
information by setting the output to 1 V or 2 mA.
PLEASE NOTE!
The sensor accuracy is defined at continuous operation (at least 3 weeks after
installation)
This product is in accordance with the EMC 2004/108/EC, 92/31/EEG including
amendments by the CE-marking Directive 93/68/EEC.
The product fulfils the following demands: EN 61000-4-2 level 2, EN 61000-4-3 level
2, EN 61000-4-4 level 4, EN 61000-4-6, EN 61000-4-8 level 4, EN 55022 class B
SenseAir® AB (headquarter)
Stationsgatan 12
Box 96
820 60 Delsbo
SWEDEN
Phone: +46-(0)653-71 77 70
E-mail: info@senseair.com
Web site: www.senseair.com
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Senseair eSENSE II - Disp at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Senseair eSENSE II - Disp in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info