735550
2
Zoom out
Zoom in
Previous page
1/4
Next page
9 Lidlocking screw
10 Wall plate
11 Screw to hold the wall plate
12 Drill marks for cable entry bushings
Dismounting the wall plate
The sensor is delivered with the wall plate mounted. The wall plate has to be removed before the
sensor is mounted onto the wall. Unscrew the screw on the side of the box.
Wall Mounting Instruction
Normally the PCB should not be removed from the housing. If for some reason the PCB must be
removed it must be handed carefully and protected from electrostatic discharge.
1) Electrical cable entry: Mount the cable entry bushing in dimension PG9. Never feed more than
one cable through each cable entry bushing, or else gas might leak through!
2) Screw the wall plate onto the wall: The wall plate has holes for three screws. Drill holes for
3,5mm screws and put dowel into them. Dowels and screws 3,5 x 25mm are included in a plastic bag
3) Attaching the sensor box to the wall plate is done by a snap-in fitting. The wall plate has three
hooks that fit in holes in the sensor box. Fasten the screw on the side of the box.
4) The lid can be locked with the screw at the bottom of the sensor box.
If for some reason the PCB must be removed it must be handed carefully and protected from
electrostatic discharge! Normally, removing the PCB is not required.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Senseair aSENSE Ind K45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Senseair aSENSE Ind K45 in the language / languages: English as an attachment in your email.

The manual is 0,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info