Operation Instruction
, Main Functions:
1. Radio-controlled function
2. weather forecast for 4 states: sunny, semi-sunny, cloudy, rainy
3. seven languages to show the day: English, Germany, French, Italian, Spanish, Dutch, Danish
4. indoor temperature range: 0℃--50℃, sampling cycle: 12 seconds
5. indoor humidity range: 20%-----95%
6. outdoor temperature with RF: up to 3 channels
7. in/out trend indication of temperature
8. indication of the comfort index
9. the function of Alarm/ Snooze
10. 12/24 hour selectable
11. moon phase
12. LED light
13. world time zone set, -12/+12 hours
. Power-On and reset
1. When Power-On and reset, LCD full display for 3 seconds enter the normal state after “Beep” check temperature and humidity
2. The calendar defaults 0:00 January 1, 2004
3. Alarm defaults 0:00
4. The weather icon defaults semi-sunny
5. Temperature scales defaults Celius degree . Time system defaults 24Hr.
. instruction of operating the KEYS
3.1 Key functions
Six functional keys: Set, Alarm, Up, Down, Snooze, Channel
Clock Alarm Up Down SNZ/LIGHT Channel Alert Max/Min
standard mode
Click ----- Alarm
on/off
12hr/24hr
switchable °C/°F
switchable
Back Light/
enter Snooze
Switch to
CH1,CH2,CH3
On/Off
temperature
Alarm
Switchable
between
CH1, 2, 3
Hold enter into
clock setting
enter into
alarm setting
----- ----- ----- Clear
current
registered
Into
temperature
alarm setup
clear max/
min
Time set
Click Confirm the
setting item
----- one step
forward
one step
backward
----- --------- ---------- ----------
Hold ----------- ----- 8steps/second
forward
8steps/second
backward
----- --------- ----------- ----------
Alarm set
Click ---------- confirm the
setting item
one step
forward
One step
backward
----- --------- ------------ --------
Hold ---------- ----- 8steps/second
forward
8steps/second
backward
----- --------- ------------ -----
Temp alert set
Click
-----------
-----
one step
forward
one step
backward
-----
Choose
needed
channel
Confirm the
Setting item
---------
Hold
----------
------
8steps/second
forward
8steps/second
backward
-----
------
------
----------
3.2 Normal states
1. hold “clock” for 2 seconds to enter into time setting
2. click “Alarm” to switch the alarm on/off
3. hold “Alarm ” for 2 seconds to enter into Alarm setting
4. click “Up” to switch between 12hr/24hr
5. press “Down” to switch between °C/°F
6. press”SNZ/LIGHT”to turn on the back light 5 second
7. when ALARM rings, click “SNZ/LIGHT” to enter into the snooze state every 5 minutes
8. press “Channel” to switch RF channel, CH1 CH2CH3
9. hold “Channel” key for 2 seconds to clear out all data of current “Channel”
10. press”ALERT”key to switch temperature alarm on/off
11. hold”ALERT”key 2 seconds to enter temperature alarm setting
12. press”MAX/MIN”key to check maximal and minimum of temperature and humidity
13. hold”MAX/MIN”key 2 seconds to clear all record of temperature and humidity
3.3 Time set
1. hold “clock” key for 2 seconds to enter into time setting
2. the sequence of time setting: Year(2000-2050) Month Date Language Hour Minute Time zone Exit
Function
Operation
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sencor SWS 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sencor SWS 30 in the language / languages: English as an attachment in your email.

The manual is 0,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info