Function
Function:
the time switch automatically opens and closes a circuit according to a
weekly program established by plugging jumpers onto a moving dial.
Contact status
display switch
Fixed mark
Jumper support
moving dial
Inscription in hours
Inscription in days:
I
= Monday
II
= Tuesday
III
= Wednesday
IV
= Thursday
V
= Friday
VI
= Saturday
VII
= Sunday
Manual switch for
forcing ON or OFF
1
4
25
6
3
Applications
For loads less than 3500 W.
For loads exceeding 3500 W, use in conjunction with
a contactor.
Programming
Program the status change order of the contact by
placing in turn red jumpers (load startup), contact
between terminals 2 and 3, and green jumpers (load
stopping), contact between terminals 1 and 2.
Setting limits:
minimum gap between 2 slots on the dial = 1 hour
minimum gap between 2 jumpers = 4 hours.
Red jumper
Rotation
direction
Green jumper
In the above example, the load will be on from Monday
at 0h00 to Wednesday midnight.
5
Setting
To set the day, turn the
graduated dial in the
direction shown to bring
the figure for the
required day opposite
the fixed mark.
To set the hour, turn
the dial to bring the
figure for the required
hour opposite the fixed
mark.
A quartz motion
(ARM) starts after a few
minutes.
Check proper
operation of switching
by rotating the
switch .
6
5
1
Selecting ON,
OFF or
automatic
mode
Using switches
and in conjunction
with one another, the
switch can be set for
automatic operation,
forced ON or forced
OFF:
switch on "perm":
permanent on or off
(using switch ),
switch on "auto":
operation as in preset
program.
1
3
3
Characteristics
Supply voltage: 230 V Ac 10%
Frequency: 50-60 Hz
Rating: 16 A/250 V cosϕ = 1; 4 A/250 V cosϕ = 0.6
Consumption: 2.5 VA
Quartz motion
Operating reserve: 150 hours
Minimum time between 2 switchings: 4 hours
Type of setting: 1 B STU according to EN 60730
Operating temperature: -10 °C to +50 °C
Terminals capacity: 6 mm
2
Overall dimensions: 6 modules of 9 mm.
Acceptable power
incandescent lamp 230 V1100 W
halogen lamp 230 V1100 W
non compensated fluorescent tube/serial compensated
fluorescent tube with conventional ballast
15 x 40 W - 10 x 58 W
6 x 100 W
parallel compensated fluorescent tube with conventional
ballast
2 x 40 W (4.7 µF)
1 x 58 W (7.0 µF)
dual-mounted fluorescent tube with conventional ballast5 x (2 x 58 W) - 3 x (2 x 100 W)
parallel compensated sodium vapour lamprelay by contactor CT
parallel compensated HQL fluorescent balloonrelay by contactor CT
Need help? Post your question in this forum.
Report abuse
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Schneider Electric Merlin Gerin Multi 9 IH 15367 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Schneider Electric Merlin Gerin Multi 9 IH 15367 in the language / languages: English as an attachment in your email.
The manual is 0,15 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
Others manual(s) of Schneider Electric Merlin Gerin Multi 9 IH 15367
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.