613773
1
Zoom out
Zoom in
2
1
3
4
Réalisation : AMEG 04 76 70 05 55
1558902BC
Schneider Electric
Centre Merlin Gerin
F-38050 Grenoble cedex 9
tel.: +33 (0)4 76 57 60 60
This product must be installed, connected and used in compliance with
prevalling standards and/or installation regulations.
As standards, specifications, designs and dimensions develop from time to time,
always ask for confirmation of the information given in this publication.
5
6
cat. No.: 15367
en
IH
7 d - 1C ARM
1
1
2
2
3
3
8
8
4
4
5
5
6
6
7
7
0
50
0
24
22
21
20
19
18
6
15
14
13
1
0
4
3
2
1
9
8
7
6
0
50
0
0
50
0
24
22
21
20
19
18
6
15
14
13
1
0
4
3
2
1
9
8
7
6
0
50
0
I
H
1
53
6
7
mult
i
9
M
E
R
L
I
N
G
E
R
IN
Function
Function:
the time switch automatically opens and closes a circuit according to a
weekly program established by plugging jumpers onto a moving dial.
Contact status
display switch
Fixed mark
Jumper support
moving dial
Inscription in hours
Inscription in days:
I
= Monday
II
= Tuesday
III
= Wednesday
IV
= Thursday
V
= Friday
VI
= Saturday
VII
= Sunday
Manual switch for
forcing ON or OFF
1
4
2 5
6
3
Applications
For loads less than 3500 W.
For loads exceeding 3500 W, use in conjunction with
a contactor.
Programming
Program the status change order of the contact by
placing in turn red jumpers (load startup), contact
between terminals 2 and 3, and green jumpers (load
stopping), contact between terminals 1 and 2.
Setting limits:
minimum gap between 2 slots on the dial = 1 hour
minimum gap between 2 jumpers = 4 hours.
Red jumper
Rotation
direction
Green jumper
In the above example, the load will be on from Monday
at 0h00 to Wednesday midnight.
5
Setting
To set the day, turn the
graduated dial in the
direction shown to bring
the figure for the
required day opposite
the fixed mark.
To set the hour, turn
the dial to bring the
figure for the required
hour opposite the fixed
mark.
A quartz motion
(ARM) starts after a few
minutes.
Check proper
operation of switching
by rotating the
switch .
6
5
1
Selecting ON,
OFF or
automatic
mode
Using switches
and in conjunction
with one another, the
switch can be set for
automatic operation,
forced ON or forced
OFF:
switch on "perm":
permanent on or off
(using switch ),
switch on "auto":
operation as in preset
program.
1
3
3
Characteristics
Supply voltage: 230 V Ac 10%
Frequency: 50-60 Hz
Rating: 16 A/250 V cosϕ = 1; 4 A/250 V cosϕ = 0.6
Consumption: 2.5 VA
Quartz motion
Operating reserve: 150 hours
Minimum time between 2 switchings: 4 hours
Type of setting: 1 B STU according to EN 60730
Operating temperature: -10 °C to +50 °C
Terminals capacity: 6 mm
2
Overall dimensions: 6 modules of 9 mm.
Acceptable power
incandescent lamp 230 V 1100 W
halogen lamp 230 V 1100 W
non compensated fluorescent tube/serial compensated
fluorescent tube with conventional ballast
15 x 40 W - 10 x 58 W
6 x 100 W
parallel compensated fluorescent tube with conventional
ballast
2 x 40 W (4.7 µF)
1 x 58 W (7.0 µF)
dual-mounted fluorescent tube with conventional ballast 5 x (2 x 58 W) - 3 x (2 x 100 W)
parallel compensated sodium vapour lamp relay by contactor CT
parallel compensated HQL fluorescent balloon relay by contactor CT


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Schneider Electric Merlin Gerin Multi 9 IH 15367 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Schneider Electric Merlin Gerin Multi 9 IH 15367 in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Schneider Electric Merlin Gerin Multi 9 IH 15367

Schneider Electric Merlin Gerin Multi 9 IH 15367 User Manual - Dutch - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info