745565
5
Zoom out
Zoom in
Previous page
1/28
Next page
5
TECHNICAL DATA AND DIMENSIONS
Intermittent operation in this context means normal use
of a wood-burning stove. In other words, you should let
the fire die down until only the embers are left before
refueling.
This stove is produced in accordance with type approval
for the product, which also covers the product’s Assembly
and Instruction Manual.
The Declaration of Performance (DoP) is available from
www.scan.dk
*
Scan 41-1 - Test in compliance with EN 13240
CO Emission at 13% O
2
0,08 %
CO
Emission at 13% O
2
975 mg/Nm
3
Dust @ 13% O
2
<20 mg/Nm
3
No
x
@ 13% O
2
104 mg/Nm
3
Efficiency 82 %
Energy efficiency index 110
Energy efficiency class A+
Nominel output 6 kW
Chimney temperature EN 13240 221 °C
Temperature in flue conn. piece 300 °C
Amount of smoke 5 g/sek
Sub-pressure EN 13240 12 Pa
Recommended sub-pressure in
connecting piece
15-18 Pa
Required combustion air supply 13,3 m
3
/h
Fuel Wood
Fuel consumption 2 kg/h
Amount of fuel required to light 1,5 kg
Scan 41-2 - Test in compliance with EN 13240
CO Emission at 13% O
2
0,1 %
CO
Emission at 13% O
2
1221 mg/Nm
3
Dust @ 13% O
2
<20 mg/Nm
3
No
x
@ 13% O
2
117 mg/Nm
3
Efficiency 79 %
Energy efficiency index 106
Energy efficiency class A
Nominel output 6 kW
Chimney temperature EN 13240 240 °C
Temperature in flue conn. piece 305 °C
Amount of smoke 6 g/sek
Sub-pressure EN 13240 12 Pa
Recommended sub-pressure in
connecting piece
15-18 Pa
Required combustion air supply 12,5 m
3
/h
Fuel Wood
Fuel consumption 2 kg/h
Amount of fuel required to light 1,5 kg
Materials
Steel plate
Cast iron
Galvanised sheet
Vermicolite
Surface treatment Senotherm
Max. wood length 30 cm
Weight Scan 41-1 and Scan 41-2 ca. 119 kg
Connecting piece internal diameter 144 mm
Connecting piece external diameter 148 mm
Approval type Intermittent fuelling*
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan 41 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan 41 in the language / languages: English as an attachment in your email.

The manual is 3,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan 41

Scan 41 User Manual - German - 28 pages

Scan 41 User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info