Manual SA 250
pag. 16
PCG/C SA 250 Manual 27-03-07
12. Add weights for the 3
e
point of adjustment upon the scale.
(This is not necessarily the max. weighing capacity)
13. Press key to enter the measured weight signal.
14. Enter the value of this weight with the keys
(increase) and (switch left)
The symbol F3 indicates this second point of adjustment.
15. Press key to enter the value of the weight
.
16. The display now asks for the value of the maximum scale capacity.
The display shows:
SP 2 , the figure at the right flashes and may be edited
now with key .
With key the next figure is made editable, and so on.
During normal operation of the scale the weight reading will switch off and
show “overload” at loadings above this weight value + 9 divisions.
17. Press key to enter the value of the maximum weighing capacity.
The display shows CAL during the entering procedure.
The adjustment procedure will now be finished and the scale will
automatically return to the normal weighing mode.
8. Remove the weight from the weigh platform.
19. Switch the scale off and on again. All keys will be accessible now.
The scale is ready to be used.
WEEGTECHNIEK HOLLAND B.V. Website www.weegtechniek.nl Tel +31 36 522 20 30
Patroonsweg 23-27 Email info@ weegtechniek.nl Fax +31 36 522 20 60
3892 DA ZEEWOLDE The Netherlands
F 3
F 3
SP 2
SP 2
NET
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satex . . SA 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satex . . SA 250 in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satex . . SA 250

Satex . . SA 250 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info