Every 15 minutes, the detector sends a transmission with information on the current status of
the reed switch, tamper contact and battery. Periodic transmissions are used to monitor
presence and operation of the magnetic contact.
Note: In the case of the AMD-103 magnetic contact, the presence check is performed in
a different way than for the other ABAX system devices. If the value programmed for
the F
ILTER
parameter differs from 0, the lack of presence will be reported if no
transmission from the detector is received within one hour.
The LED is only working in the test mode:
it is lit for 80 milliseconds, when the test transmission is being sent;
it is lit for 2 seconds in the event of alarm.
The test mode is turned on for 20 minutes after inserting the batteries or opening the tamper
contact.
The detector checks the battery status. When the voltage is lower than 2.6 V, the low-battery
information is sent during each transmission.
4. Installation
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
The device is designed for indoor installation. The detector should be mounted on a fixed
surface (e.g. window or door frame), and the magnet on a movable surface (e.g. window or
door). Mounting the magnetic contact on ferromagnetic surfaces and/or near to strong
magnetic and electrical fields is not advisable, because it can result in malfunctioning of the
device.
Special designation on the detector enclosure indicates the side on which the magnets
should be installed (Fig. 6).
1. Open the detector enclosure (Fig. 2).
2. Install the battery and add the device to the wireless system (see the ACU-100 / ACU-250 /
ACU-120 / ACU-270 controller manual, installer manuals for INTEGRA 128-WRL or
VERSA control panels).
3. Close the detector enclosure (the tamper contact must be pressed down by the base
element).
4. Fasten the detector temporarily at the place of its future installation.
5. Move the magnet away from the detector. The detector will send information on the alarm,
which will allow you to check the level of signal received from the detector by the
ACU-100 / ACU-250 / ACU-120 / ACU-270 controller or the INTEGRA 128-WRL control
panel. If necessary, select another place for installation, to ensure adequate
communication quality.
6. Open the detector enclosure (Fig. 2).
7. Using wall plugs (screw anchors) and screws, fasten the enclosure base to the mounting
surface (Fig. 3).
8. Close the detector enclosure (the tamper contact must be pressed down by the base
element).
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel AMD-103 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel AMD-103 in the language / languages: English as an attachment in your email.

The manual is 0,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel AMD-103

Satel AMD-103 User Manual - German - 4 pages

Satel AMD-103 User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info