ELECTROMAGNETIC COMPATIBILITY INFORMATION
Guidance and manufacturer’s declaration - electromagnetic emissions
The SIL 45 is intended for use in the electromagnetic environment specified below.
The customer or the user of the SIL 45 should assure that it is used in such an environment.
Emissions Compliance Electromagnetic environment - guidance
RF emissions
CISPR 11(EN 55011)
Group 1 The SIL 45 uses RF energy only for its internal function. Therefore, its
RF emissions are very low and are not likely to cause any interference
in nearby electronic equipment.
RF emissions
CISPR 11 (EN 55011)
Class B The SIL 45 is suitable for use in all establishments, including domestic
establishments and those directly connected to the public low-voltage
power supply network that supplies buildings used for domestic pur-
poses.
Harmonic emissions
IEC 61000-3-2
(EN 61000-3-2)
Class A
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
(EN 61000-3-3)
Complies
Guidance and manufacturer’s declaration - electromagnetic immunity
The SIL 45 is intended for use in the electromagnetic environment specified below. The customer or the user of the SIL 45
should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment
--guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
(EN 61000-4-2)
±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
Floors should be wood, con-
crete or ceramic tile. If floors
are covered with synthetic
material, the relative humidity
should be at least 30 %.
Electrical fast transient/
burst IEC 61000-4-4
(EN 61000-4-4)
±2 kV for power
supply lines
±2 kV for power
supply lines
Mains power quality should be
that of a typical commercial or
hospital environment.
Surge
IEC 61000-4-5
(EN 61000-4-5)
±1 kV line(s) and neutral ±1 kV line(s) and neutral Mains power quality should be
that of a typical commercial or
hospital environment.
Voltage dips, short in-
terruptions and voltage
variations
on power supply
input lines
IEC 61000-4-11
(IEC 61000-4-11)
<5 % U
T
(>95 % dip in U
T
)
for 0,5 cycle
40 % U
T
(60 % dip in U
T
)
for 5 cycles
70 % U
T
(30 % dip in U
T
)
for 25 cycles
<5 % U
T
(>95 % dip in U
T
)
for 5s
<5 % U
T
(>95 % dip in U
T
)
for 0,5 cycle
40 % U
T
(60 % dip in U
T
)
for 5 cycles
70 % U
T
(30 % dip in U
T
)
for 25 cycles
<5 % U
T
(>95 % dip in U
T
)
for 5s
Mains power quality should be
that of a typical commercial
or hospital environment. If a
dips or an interruption of mains
power occurs, the current of
the SIL 45 may be dropped off
from normal level, it may be ne-
cessary to use uninterruptible
power supply or a battery.
Power frequency
(50/60 Hz) magnetic field
IEC 61000-4-8
(IEC 61000-4-8)
3 A/m Not applicable Not applicable
NOTE U
T
is the a.c. mains voltage prior to application of the test level
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas SIL 45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas SIL 45 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info