684537
44
Zoom out
Zoom in
Previous page
1/46
Next page
43
English
Installation
Installation Inspection
Step 4.1 Performing the gas leak tests
1. Before inspecting the leakage, use a torque
wrench to close the cap for the stop valve.
(Comply with a tightening torque for each size
of the diameter, and tighten the cap firmly to
prevent any leakage.)
Tightening torque for body cap
(Refer to the table)
Spindle
Charging core
R-22: Thread of the screw - 7/16-2OUNF
R-410A: Thread of the screw -1/2-2OUNF
Tightening torque for charging port cap (Refer to the table)
2. Insert inert gas into the pipes connected to indoor
and outdoor units.
3. Test leakage on the connection parts of the indoor
and outdoor units with soap lather or liquid.
Test parts for the
indoor unit
Test parts for the
indoor unit
Test parts for the
indoor unit
Test parts for the
indoor unit
Step 4.2 Running the Smart Install mode
1. Make sure that the air conditioner is in the
standby status.
2. Hold down the
(Power), (Mode), and
(SET) buttons on the remote control
simultaneously for 4 seconds.
3. Wait until Smart Install mode succeeds or fails. It
takes approximately 7 to 13 minutes.
While Smart Install mode is proceeding:
Type
Display
LED Display
Indoor
unit
indicator
LED1
LED2
LED3
The progress is
displayed as a
number between
0 and 99 on
the indoor unit
display.
The LEDs on
the indoor unit
display blink in
sequence, then
all of them blink
simultaneously.
These operations
repeat.
When Smart Install mode succeeds: Smart
Install mode ends with ringing sound, and the air
conditioner is in standby status.
When Smart Install mode fails: An error message
is displayed on the indoor unit display, and Smart
Install mode ends.
NOTE
Smart Install mode can be operated only with the
supplied remote control.
During the Smart install mode procedure, remote
control cannot be operated.
Outer diameter
(mm)
Tightening torque
Body cap
(N•m)
Charging port cap (N•m)
ø 6.35 20 to 25
10 to 12
ø 9.52 20 to 25
ø 12.70 25 to 30
ø 15.88 30 to 35
Over ø 19.05 35 to 40
( 1 N•m = 10 kgf•cm )
DB68-06031A-01_A5.indd 43 4/18/2017 9:00:04 AM
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Samsung AR..HPFS.. at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Samsung AR..HPFS.. in the language / languages: English as an attachment in your email.

The manual is 21,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info