735258
2
Zoom out
Zoom in
Previous page
1/2
Next page
5
8
16
3A
3
9
5
3
5
5
6
12
15
8
6
3
2
1
11
1
14
1
1
7
1
3B
4
10
13
6
7
4
13A 13B
12
2
15
2
2
8
2
4
4
4
5
11
14
7
Press SELECT to confirm.
Press SELECT to confirm.
The thermostat will go to
the main screen.
Using UP or DOWN, select the
program type between: 5
Using UP or DOWN, enter the PIN
code number. Press SELECT to
confirm every digit.
Press SELECT.
Using UP or DOWN, select
TEST and press SELECT.
Individual (set a daily schedule).
Press SELECT to confirm.
Using UP or DOWN, select the due
date and then press SELECT.
Using UP or DOWN, set the
temperature and then
press SELECT.
Press SELECT.
Using UP or DOWN, select the TPI type you want to use.
Press SELECT.
Using UP or DOWN,
select ON or OFF.
Using UP or DOWN,
select ON or OFF.
Press MENU.
Press MENU.
Using UP or DOWN, select
the warning period and
then press SELECT.
Press MENU.
+2 (schedule for the working days
and for the weekend);
Press SELECT.
Using UP or DOWN, enter the
phone number. Press SELECT to
confirm every digit.
Using UP or DOWN, set the hour
and then press SELECT.
Using UP or DOWN, select the
Span value.
Press SELECT to confirm.
Press SELECT.
Press SELECT to confirm.
Press SELECT.
Using UP or DOWN, navigate to
Landlord submenu
and press SELECT.
Using UP or DOWN, select the
lock temperature and
then press SELECT.
Using UP or DOWN, navigate to
Pairing submenu and press SELECT.
The testing process takes
up to 10 minutes.
The red LED and the green
LED on the receiver
will begin to flash.
The pairing process takes
up to 10 minutes.
All (set one schedule for
the entire week)
Using UP or DOWN, select ON
and press SELECT.
Now you can check your
settings. If you want to
make a change, press UP
or DOWN on the relevant
screen.
Using UP or DOWN, set the
minutes and then press SELECT.
TPI (Time Proportional & Integral) is a self-learning, time-
proportional algorithm. TPI type of regulation ensures economical
system operation through more accurate temperature maintenance
during controlling process and limits overload conditions. In addition
to the exact and stable room temperature, the advantage of this
system is the minimization of energy consumption and significant
savings. RT520 offers 3 types of TPI control: 1. for radiator (6CPH); 2.
for underfloor heating (3CPH); 3. for electric heating (9CPH).
Optimum Stop calculates how
long the house will take to cool
down, then turns off the boiler at
the earliest possible moment, this
means the system is not running
when it’s not actually necessary. If
there is a sudden heat loss during
this period, then Optimum Stop will
be overridden to regain comfort
conditions.
Landlord settings is a pin code protected feature that allows the landlord to set a service reminder on the
thermostat that will warn the tenant when the boiler is due its annual service.
Span is the difference between the
measured temperature and the set
temperature.
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods of
time). Programmed schedules should use all time periods.
If you are using the RT520RF pack, the pairing between the thermostat and the receiver is
already done.
During the pairing process, please make sure the thermostat and the receiver are at least 1
meter from each other.
If you bought the RT520TX and RXRT520 separately or if you want to re-pair thermostat with
the receiver, make sure that the device is disconnected from the power supply and the switches
on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply
and wait for the red LED to light steadily. Then switch to the OFF position and again to ON
position quickly. The red ashing LED will conrm entering the pairing mode.
Once devices are successfully
paired, LED on the receiver
will go solid red.
The device will be reset and will
start up automatically.
To reset the thermostat, press MENU,
DOWN and BOOST simultaneously
for 5 seconds.
Repeat the process for all time periods.
Once service mode has become active, the device will lock the set point temperature as set
by the installer/landlord. To unlock this device, the landlord needs to be contacted and the
boiler serviced.
Landlord settings will not be reset.
Programming - Automatic Mode
RT520TX Thermostat Pairing with the ReceiverLandlord Settings
Factory Reset
Test the Pairing Process
ON
AUTO
OFF
MANUAL
ON
AUTO
OFF
MANUAL
Standard Power Up and Conguration
Please follow steps 1 to 17 from section OpenTherm Power Up and Configuration.
NOTE: Using UP or DOWN, you can choose either TPI (step 2) or SPAN (step 6). Choosing one
option excludes the other.
9
10A 10B
Press SELECT.Press SELECT.
Optimum Start is a selectable function which, depending on the ambient
room temperature, will start the boiler operation at the optimum time to
achieve the set-point temperature. It saves energy by only firing the boiler
for the minimum required time.
31 2
Using UP or DOWN, select PAIR
and press SELECT.
Press MENU. Using UP or DOWN, navigate to
Pairing submenu and press SELECT.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Salus RT520RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Salus RT520RF in the language / languages: English as an attachment in your email.

The manual is 6,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Salus RT520RF

Salus RT520RF Quick start guide - German - 2 pages

Salus RT520RF Quick start guide - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info