735249
1
Zoom out
Zoom in
Previous page
1/2
Next page
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
4
6
8
10
Introduction
Button functions
LCD Icon description
Technical specication
Product compliance
Safety Information
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU.
Full information is available on the website www.saluslegal.com
RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device
launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to national
and EU regulations.
RT510/RT510TX Thermostat RXRT510 Receiver
1
6
7
8
9
4
3
2 5
1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode,
OFF will turn the boiler o.
8. Receiver operates in automatic mode
according to the thermostat
9. Receiver output is controlled
by the On/O slide switch.
1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock
2
3 5 6
4
1
15 14 1213
8
9
11
7
10
RT510 Thermostat RT510TX Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
Outputs
Voltage free
NO / COM / NC
terminals
-
Temperature range 5 - 35°C 5 - 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Control algorithm
TPI or hysteresis ±0.25°C TPI or hysteresis ±0.25°C
Radio frequency - 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96x96x27
Importer:
SALUS Controls plc
Salus House, Dodworth Business Park
Whinby Road, Barnsley S75 3SP,
United Kingdom
DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
Installation Manual
Model: RT510 (Wired, electronic thermostat - programmable)
RT510RF (Wireless, electronic thermostat - programmable)
DIP Switch Settings
RT510 Wiring diagram
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
OR
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
RT510
Thermostat
RT510
Thermostat
RT510RF Wiring diagram
Setting the time
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
OR
RT510TX
Thermostat
RT510TX
Thermostat
RXRT510
Receiver
RXRT510
Receiver
RT510 Terminals description
RXRT510 Receiver terminals description
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
NO COM L N
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SET to conrm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
I 2018
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
Programming - automatic mode
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
4
6
8
10
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to dene programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods
of time). You have the option to choose between a 5-2 days programme or a daily one by using the
parameter d04 from Installer mode.Programmed schedules should use all time periods.
Control feature TPI Span
Operation When TPI is selected on
DIP switch № 2, the DIP
switch № 1 is functional.
You can choose the
Cycles Per Hour between
a lower comfort level
(6CPH) and a higher
comfort level (9CPH).
When Span is selec-
ted on DIP switch №
2, the DIP switch №
1 is not functional.
The SPAN value is set
to ± 0.25 °C - it is
recommended to use
with heating devices.
9CPH
±0.25°C
6CPH
Span
TPI
ON
1 2
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Salus RT510RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Salus RT510RF in the language / languages: English as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Salus RT510RF

Salus RT510RF User Manual - German - 2 pages

Salus RT510RF User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info