541991
2
Zoom out
Zoom in
Previous page
1/2
Next page
WIRING PLAN
Terminal
Supply for temperature reduction
N Neutral wire
L 230 VAC supply
Switch output (actuator, terminal strip)
PROGRAM-MENU
Program Menu
To access the program-menu press
the or + button, open the hatch and
press select and cancel at the same
time for three seconds.
Heat/Cool
Enter the Heat/Cool-Menu to activate the
Heat or Cool function of the device.
Control
Enter the Control-Menu to make changes on the
Span, SetBack, Frost*, Output and VP settings.
* Thermostat serves as protection against frost
and keeps temperature constant at 5°C.
Daytimes Time Family Single Office Name 1 Name 2
Mon - Fri
Eearly Morning
Morning
Noon
Afternoon
Evening
Night
06:00 - 08:00
08:00 - 12:00
12:00 - 14:00
14:00 - 18:00
18:00 - 23:00
23:00 - 06:00
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Sat - Sun
Eearly Morning
Morning
Noon
Afternoon
Evening
Night
06:00 - 08:00
08:00 - 12:00
12:00 - 14:00
14:00 - 18:00
18:00 - 23:00
23:00 - 06:00
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Basic Settings
Enter the Basic Settings-Menu to
adjust Date/Time, Language and
Maintenance settings.
Temp. Zones
Enter the Temp. Zones-Menu to adjust the temperatures of the Com-
fort, Standard and Reduced zones.
The three temperature zones can be allocated to the six day times.
If you modify a temperature zone, the temperature-settings within
the profiles will change as well. The zones are preinstalled with these
temeratures:
Comfort 24°C Standard 20°C Reduced 16°C
Purpose and correct use:
This standalone mounted electronic device
serves as a temperature control system only in
dry and closed living and office spaces. Clean
device only with a dry and soft cloth. Do not
use solvents or aggressive cleaning agents!
The manufacturer accepts no responsibility
for damage caused by non-observance of
these instructions.
Changing the batteries
2 x +AA Batteries
Do not dispose of batteries with
general household refuse. Please take
battery to municipal collection point
or dispose with trade waste.
Profile
Enter the Profile-Menu to adjust the detailed settings of the Family, Single, Office, Name 1 and Name 2 Profiles.
You can adjust the profiles to your needs, by varying the 6 daytimes and allocate them new temerature zones. This
can be done for a single day or week and weekend. You can rename profiles and copy settings inside a profile and
from one profile to an other. In the following table, you can find the preinstalled settings:
DATA SPECIFICATION
Supply:
2 x Batteries Type AA (intern)
230V AC / 50Hz (extern)
Electronic switch output
Switching current max.: 10 (2) A
Number of actuators, max.: 5 units - 3W
Hysteresis: 0.5K
Protective class: IP 30
Dimensions W/H/D in mm: 75/130/30
Temperature range: 5°C - 30°C
Storage temperature: -25°C - 65°C
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Salus ERT 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Salus ERT 50 in the language / languages: English as an attachment in your email.

The manual is 0,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Salus ERT 50

Salus ERT 50 User Manual - German - 2 pages

Salus ERT 50 User Manual - Dutch - 2 pages

Salus ERT 50 User Manual - Spanish - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info