489974
8
Zoom out
Zoom in
Previous page
1/11
Next page
8
RMB-1512 Twelve Channel Power Amplifier
12V Trigger Input
9
An input jack for connecting the wires carrying a +12 volt trigger
signal from a Rotel preamp or surround sound processor to turn the
amplifier on and off. To use this feature the adjacent slide switch must
be placed to the left position (see previous section).
The TRIGGER INPUT accepts any control signal (AC or DC) ranging
from 3 volts to 30 volts. Use a cable with mono 3.5 mm mini-plugs on
both ends. The +12V DC signal appears at the “tip” connector.
12V Trigger Output
9
The 12V TRIG jack labeled OUT is used to pass the remote turn-on
signal to a second Rotel amplifier. Any 12V Trigger signal at the
INPUT jack will be passed through to the OUT jack.
Protection Indicators
2
A thermal protection circuit protects the amplifier against potential
damage in the event of extreme or faulty operating conditions. Unlike
many designs, the RMB-1512’s protection circuit is independent of the
audio signal and has no impact on sonic performance. Instead, the
protection circuit monitors the temperature of the output devices and
shuts down the amplifier if temperatures exceed safe limits.
In addition, the RMB-1512 includes overcurrent protection which
operates only when load impedance drops too low.
Should a faulty condition arise, the amplifier will stop playing and
one or more of the PROTECTION LEDS on the front panel will light.
If this happens, turn the amplifier off, let it cool down for several
minutes, and attempt to identify and correct the problem. There are
independent PROTECTION LEDS for each pair of channels which may
help in troubleshooting the cause of the problem. When you turn the
amplifier back on, the protection circuit will automatically reset and the
PROTECTION LEDS should go out.
In most cases, the protection circuitry activates because of a fault
condition such as shorted speaker wires, or inadequate ventilation
causing an overheating condition. In very rare cases, highly reactive
or extremely low impedance speaker loads could cause the protection
circuit to engage.
Note: The protection LED also light when the 12V Trigger system is
being used and the amplifier is in Standby mode.
Signal Connections
The RMB-1512 provides standard conventional input connections
— unbalanced RCA type connections as found on nearly all audio
equipment.
In addition to the six groups of stereo inputs labeled INPUT 1 to
INPUT 6, there is a pair of inputs labeled LINK IN. There is also
a pair of SIGNAL OUTPUT LINK connections for passing the input
signal connected to the LINK IN pair of inputs on to another audio
component.
Additionally, the input signal to the LINK IN connectors can be
automatically linked to the inputs for any of the channel INPUTS 1-6,
so that a separate input signal cable is not required for those channels,
for example in large systems where the RMB-1512 is being used to
drive multiple pairs of speakers.
RCA Inputs
4
See figure 2
are two RCA inputs for each of the six pair of amplifier channels.
These RCA inputs accept audio signals from preamplifiers or surround
sound processors. Use high quality audio interconnect cables for best
performance.
For each pair of amplifier channels, connect the left channel output of
your preamp to the LEFT INPUT on the RMB-1512. Connect the right
channel of your preamp to the RIGHT INPUT. Make sure that the input
slide switch to the right of the RCA inputs is in the STEREO position.
Linking the Inputs
4
You can link the inputs for any of the group 1–6 inputs by moving the
input slide switch below each pair of RCA inputs to the LINK position.
When linked, no input connection is required for that group. The
input signal from the LINK IN connections is sent to the linked pair of
channels, allowing you to use up to twelve amplifier channels with the
same stereo input signals.
Mono Switch
4
For the groups INPUT 1 and INPUT 2, when the input slide switch is
moved to the MONO position, the left and/or right channel input is
provided to both speakers as a mono signal.
Input Level Controls
3
Six controls on the front panel, one for each pair of channels, provide
input level adjustments. These allow you to adjust the gain of the
amplifier to match other components in the system. The INPUT 1 level
control changes the gain of the INPUT 1 channels; the INPUT 2 level
control changes the INPUT 2 channels and so on. To adjust these
controls, use a small, flatblade screwdriver. Turn the control clockwise
to increase gain. Turn counterclockwise to reduce gain.
Signal Output Link
6
This pair of RCA connections can be used to pass unprocessed input
signals to another audio component, for example to “daisy-chain” an
additional amplifier to drive an additional set of speakers. The input
signals connected to the LINK IN connectors is available at these LINK
OUT outputs. This is typically used when the amplifier is part of a multi-
room system.
Note: The input signals from the LINK IN inputs can also be linked
to any of the INPUT 1-6 inputs by moving the INPUT SELECT switch
associated with that pair of channels to the LINK position.
Speakers
See Figure 2
The RMB-1512 has six groups of speaker connectors, one for each
pair of amplifier channels. The twelve channels may be used in many
different configurations. The Hook-up Illustration, Figure 2, shows just
one example, with the connections for a typical six-speaker system.
Here, the remaining six channels are still available to power up to six
further speakers as required, whether these are additions to the main
system or independent of it.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rotel RMB-1512 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rotel RMB-1512 in the language / languages: English as an attachment in your email.

The manual is 1,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info