651358
1
Zoom out
Zoom in
LAHC5
CLASS 1 PRODUCT
CONTAINING
CLASS 3B LASER
808nm
wavelength
Wearing laser
safety goggles is
unnecessary as
the product has
been designed
with inbuilt safety
features.
PATENTS PENDING
This product MUST be used responsibly.
Please read these Instructions carefully
before use.
Refer to your Information Guide for:
• WARNINGS
• SECURITYBUTTONSEQUENCE
• HOWDOLASERSWORK?
• SUITABLESKINTYPES
• PATCHTEST
• HAIRGROWTHCYCLE
• WHYISASERIESOFTREATMENTS
REQUIRED?
• YOURQUESTIONSANSWERED
• TROUBLESHOOTING
SALON LASER
SCANNING HAIR REMOVER x60
WARNINGS
• Readallinstructionsthoroughlyandretainforfuturereference.
• NotsuitableforAfro-Caribbean, black skincomplexionsor forGreyHair.
See“SuitableSkinTypes”inInformationGuide.
• Laserhairremovalshouldnotcausediscomfort,youmayfeelindividualhairs
beingtreated,whichislikeamildpinprick,andaslightwarmingofthearea.
Ifyoufeelanydiscomfortorsorenessthesettingmaybetoohigh.
• Inbuiltsafetyfeaturesprotecttheeyebeingexposedtothelaser,however,
neveraimtheWandatorneareyes.
• DoNOTusenearflammablematerials.
• Keeptheproductoutofreachofchildrenandpets.
• ReflectionHazard:Pleaseremovealljewelleryinthevicinityofthetreatment
areabeforeuse.
• Whennotinuse,storethekeyresponsiblyinasafeplaceawayfromchildren.
• Donottreatthesamehairrepeatedlyinanyonesession.
• Donotuseafterdrinkingalcoholorifyouarefeelingunwellorfatigued.
• Donottreatthefollowingareas:tattoos,permanentmake-up,pimples,warts,
haironblackspotsormoles,darkfreckles,skindisease,birthmarks,burns,
lips,nipples,genitaloranalareas,eczema,eyelashes,eyebrows,nearthe
eyes,nasalorearhair.
• Thisisasensitivelaserscanningproduct.Careshouldbetakentoavoid
damagetothemechanismintheWand.
• Thisapplianceisnotintendedforusebypersonswithreducedphysical,
sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
they have been given supervision or instruction concerning use of the
appliancebyapersonresponsiblefortheirsafety.
PRECAUTIONS
• DoNOTdismantleorrepair.Ifyouhaveanyproblemsusingtheproduct,
contactourCustomerCareDepartment.
• Misuseoftheunitcancauseharm.
• DoNOToverrideanysafetyfeaturesoropentheunitorwand.
• OnlyusethisproductwiththeMainsAdaptersupplied.
• KeepWandawayfromstrongelectromagneticfieldsandmagnetsduringuse.
PATCHTEST
IMPORTANT:24hoursbeforetreatmentitisveryimportanttodoapatchtest.
Thepatchtestwillconfirmthemaximumpowerlevelforyourskintype.Eacharea
tobetreatedmustbecheckedasskincolourcanvary.Pleaserefertothe‘PATCH
TEST’sectionintheInformationGuideandontheDVDforinstructions.
Aslightrednessmayoccur,butnotalways,withinanhouroftreatment.This
localisedrednessiscausedbythedestructionofthehairfolliclesandisquite
normal.However,ifanyrednessremainsafter24hoursthiswouldindicatethe
powerlevelselectedwastoohighforyourskintype.
GETTINGSTARTED
Please ensure you read the Information Guide and understand the
‘Warnings’ and ‘Product Safety’ sections before proceeding.
• Shavetheareatobetreated.Thisensuresthatthelasergoesdirectly
tothehairrootandavoidshairburningonthesurface.
• Removealljewelleryinthevicinityofthetreatmentarea.
• Pleaseensureyouhavepatchtestedtheareatobetreated24hours
prior to treatment.
STEP 1
ConnectMainsAdapterintotheDCPowerSocketat
thebackoftheunitandplugintotheMains.
STEP2
Unlock with Key to turn on. The light around the
Keyswitchwillflashgreen.
STEP 3
Enterthe“SECURITYBUTTONSEQUENCE”.
You will find the Security Button Sequence in the
Information Guide.
ThegreenlightaroundtheKeyswitchwillfullyilluminate.
Thelightsaroundthex60SCAN,x20SCANandSINGLE
buttonswillflashbluereadyforselection.Thebottom
PowerLevelIndicatorlightwillilluminate.
STEP4
Usethe+/-buttonstoselectthecorrectpowerlevel
foryourskintype.Refertothe‘PatchTest’sectionof
theInformationGuideforskintypes.
Each time the power setting is adjusted, you will
need to reselect x60 SCAN, x20 SCAN or SINGLE
modetocontinue.
Note:Ifnobuttonsarepressedafter20minutestheUnitwillenterenergy
savingmode.The orangelightwill flashandpower level1 will remainon.
TorestartturnkeyoffandbackonagainandstartatStep3.
ADDITIONALINFORMATION
STEP 8
Turn the Keyswitch anticlockwise to lock the unit.
RemovetheKeytoasafeplaceawayfromchildren.
Note: Ifyouexperienceunexpectedbehaviourofthisproductthenitispossible
someexternalelectromagneticinterferenceisresponsiblee.g.electricmotors/
loudspeakersetc.Youshouldremovethissourceandrestarttheproductto
restorefulloperation.Atnotimewillthelaserfireunintentionally.
‘SINGLE’HAIRTREATMENT
Youcanopttotreatsinglehairsusing
theSINGLEmode.
Press the ‘SINGLE’ button once.
TheSINGLEbuttonwillilluminateblue.
The orange light on the Wand
willilluminate.
FollowthesameprocedureforSCANtreatmentfromStep6,butthistime
pressing the SINGLE button.
InSINGLEmode,thebluelightaroundtheSINGLE
buttonwillflash.
Referto‘TreatmentArea’section,SINGLEmode.
SECURITY
BUTTON
SEQUENCE”
TREATMENTAREA
Asaguidetothetreatmentarea,asmallindentationmarkwillbeleftby
pressingtheWanddownontheskin.Inx60SCANmode,overlapping
theindentationmarkslightlywhenmovingtheWandineachdirectionwill
ensureeffectivecoverage.Inx20SCANmode,overlaptheindentation
markbyhalf.
SCANmodessequentiallytargetsinglehairsineachtreatment.
SINGLEmodeisfortreatingindividualhairs.Thetreatmentareaisinthe
centreoftheindentationguideandmeasures1mmx1mm.
‘SCAN’HAIRTREATMENT
STEP 5
Press the x60 SCAN button once. The
blue light around the button will fully
illuminate.Theorangelightonthewand
willilluminate.
Alternatively,pressthex20SCANbuttononce.
STEP6
Placethewandontheskinovertheareayouwishtotreat,
ensuringtheTouchPinsareincontactwiththeskin.
TheorangelightwillturnOFFandthewhite‘ready’light
willturnON.
ThebluelightsaroundtheSCANbuttonwillrotateto
indicatetreatmentisreadytostart.
STEP 7
Press and HOLD the Laser Button on the top of the
wandtostartlasertreatment.
The white light will flash on and off to indicate laser
treatmentisinprogressandtheunitwillbeeprepeatedly
(thiscanbemuted).Youwillnotbeabletoseethelaser.
You may feel individual hairs being treated, whichis
likeamildpinprick,andaslightwarmingofthearea
beingtreated.
Whenthelasertreatmentceases,theorangelightwill
comebackon.Youcannowmoveontothenextareaof
hairstobetreated.
Whenmovingthewandtothenextareaofhairstobe
treatedtheTouchPinsmustberemovedbrieflyfrom
theskin.
Refertoscanmodesin‘treatmentarea’section.
IMPORTANTNOTES - please read carefully
• DoNOTmovethewandduringtreatment.Youmaynoticethewandbecomes
warmduringusethisisquitenormal.
• IfcontactislostbetweentheTouchPinsandskinduringtreatment,thewand’s
orangelightwillcomeon.Treatmentwillresumewhencontactismadeagain.
• Foryoursafety,ifthewandisnotpositionedcorrectlyontheskinsurfacefor
treatment,thewhiteandorangelightswillflashalternatelyandoperationof
thelaserwillbedisabled.
• Sometimesyou cansmell faint burningor even seea very, smallline of
smokeasthehairistreated.
• Successfullytreatedhairsdonotalwaysfalloutimmediately,butareshed
over time as they are released from the hair follicle, light rubbing can
encouragethis.
• Youmayfeela‘pinprick’sensationduringtreatment.Anylocalisedrednessafter
treatmentiscausedbythedestructionofthehairfolliclesandisquitenormal.If
anyrednessremainsafter24hoursthiswouldindicatethepowerlevelselected
wastoohighforyourskintype.Pleaserefertothe‘PatchTest’sectioninthe
InformationGuide.Anylongerlastingrednesswillalsodisappear.
LASERHAIRTREATMENT
1
2
5
8
7
3
4
PresstheMUTEbuttononthebackoftheUnittoturn
offtheBeepnoises.Pressagaintoturnbackon.
Note: Thisdoesn’tturnoffwarningbleeps.
resettingafter‘lockout’
If you experience a ‘lockout’ as indicated by
repeatedflashingofanyofthebluepowerlights,
simplyresetbyturningtheunitoffusingthekey,
waiting5secondsandturningtheunitonagain.
cleaninglaseraperture
Periodically check whether there are any smoke
deposits on the Laser Aperture. A build up of
depositswillaffecttheefficiencyofthelaser.Ifyou
noticeanydeposits,switchtheunitOFFandunplug
themainsadapter.Thensimplycleanwithalintfree
clothorcottonbud,ensuringnofibresareleftinthe
LaserAperture.
x60 SCANmode
x20SCANmode
SINGLEmode
Rio,Dezac,SalonLaserScanningHairRemoverx60andLaserSafeTechnologyaretrademarksofTheDezacGroupLtd©TheDezacGroupLtd2011anufacturedbyTheDezacGroupLtd,POBox17,Cheltenham,EnglandGL537ET
Overlapbyathird
Overlapbyhalf
treatmentarea
indentationmark
treatmentarea
indentationmark
treatmentarea
indentationmark
1-IN-LAHC5-UK/1.2
instructions
b
e
f
g
h
i
k
j
l
m
c
a
d
n
o
p
q
r
s
COMPONENTS
a. Mains Adapter
b. Keys
c. DC Power Socket
d. Mute Button
e. Keyswitch
f. Power Level Indicator
g. Power Increase Button (+)
h. Power Decrease Button (-)
i. x60 SCAN button
j. x20 SCAN button
k. SINGLE button
l. Hand-held Wand
m. Laser Button
n. Orange Light
o. White Light
p. Touch Pins
q. Laser Aperture
r. Indentation Guide
s. Front Face
laseraperture
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rio LAHC5 - Scanning Laser X60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rio LAHC5 - Scanning Laser X60 in the language / languages: English as an attachment in your email.

The manual is 1,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info