744684
3
Zoom out
Zoom in
Previous page
1/16
Next page
|3
EN
2
1. PREFACE
Explanations to symbols
...Important
Note
#8
...Hex #8
#25
...Hexalobular T25
...Useful
Tip
...Manually
#3
...Allen key #3
Dimensions
H
B T
RO-T1
F-H
R-H
RO-H
RO-T3
RO-T2
RO-S
R-S
F-S
K1-H
K2-H
K1-S
K2-S
R-
F-
Dimensions
Height [mm] 1098
Width [mm] 817
Corpus depth [mm] 424
Weight
Weight [kg] ~245
Flue pipe connection
R - Ø Flue pipe outlet [mm] 130
RO - H original angle pipe connection height [cm] 161
RO - T1 original angle pipe total depth [cm] 54
RO - T2 original angle pipe distance to rear wall [cm] 17
RO - T3 Depth from rear wall to middle of flue
pipe
[cm] 21
RO - S original angle pipe side distance [cm] 25
R - H Rear connection height [cm] 96
R - S Rear connection side distance [cm] 16
Fresh air connection
F - Ø Diameter [mm] 125
F - H Connection height [cm] 14
F - S Side distance [cm] 25
Convection air connection
K - Ø Diameter [mm] 100/100
K - H Connection height [cm] 75/60
K - S Side distance [cm] 19/31
Amount of fuel
Nominal load Part load
Amount of fuel ~2,4 kg* ~1,2 kg*
*Practical values may vary depending on fuel quality.
Technical data
Technical Data
Heating power range [kW] 4,5 - 9
Room heating capacity (depending on house
insulation)
[m³] 110 - 240
Fuel consumption [kg/h] up to 2,4
Electric supply [V]/[Hz] 230/50
Average electrical input [W] ~ 4*
Fuse [A] 2,5 AT
Efficiency [%] 83,8
CO2 [%] 10,6
CO-emission on 13% OO [mg/m
N
3
] 672
Dust emission [mg/m
N
3
] 21,5
Exhaust [g/s] 6,7
Exhaust temperature [°C] 242,6
Chimney draft requirement [Pa] 12
* without convection fan
The owner of small firing systems or the person authorised for the small
firing system is to keep the technical documentation and is to submit it to the
authorities or the chimney sweep on request.
Note
Please observe the national and European standards as well as local
regulations concerning the installation and operation of firing installations!
Packaging
Your first impression is important to us!
The packaging of your new stove provides excellent protection against damage.
However damage to the stove and accessories may still occur during transport.
Note
Therefore please check your stove on receipt for damage and completeness!
Report any deficiencies to your dealer immediately! Pay particular attention
during unpacking that the stone panels remain intact. Scratches to the
material can easily occur. Stone panels are excluded from the warrant.
The packaging of your new stove is environmentally neutral to a great extent.
Tip
The wood used in the packaging has not been surface treated and may
therefore be burnt in your woodburning stove (not in a pelletstove!). The
cardboard and film (PE) can be depolluted via the municipal waste collection
for recycling.
Electrical connection
The stove is supplied with an approx. 2m long connecting cable with a Euro-
plug. This cable is to be connected to a 230Volt/50Hz socket. The average
electrical power consumption is about 4 Watt in heating operation and approx.
150 Watt during automatic ignition. The power consumption of the convection
fan depends on the defined settings, max. up to 20W. The connection cable
must be laid in a way that there is no contact to any sharp edges or hot surfaces
of the stove.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Idea at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Idea in the language / languages: English as an attachment in your email.

The manual is 10,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Idea

Rika Idea Installation Guide - English - 48 pages

Rika Idea User Manual - German - 16 pages

Rika Idea Installation Guide - German, Dutch - 48 pages

Rika Idea User Manual - Dutch - 16 pages

Rika Idea Installation Guide - French, Italian - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info