Certification for Date 08/2002
Initial operation Subsequent operation of a REMKO air-conditioning system
Unit data based on type plates
 The room air conditioning system above was put into operation without any objections.
 The operator has been trained and the operating instructions distributed.
 The unit could not be put into operation for the reasons indicated above.
Signature of person assembling,
putting unit into operation
Company:
Street:
Postal code, city:
Stamp and signature
Executing company:
Date Operator signature
Units Connection line
Outdoor part: Indoor unit: Length: m
Type of unit: RKS H – AT RKS H – IT Height difference: m
Unit number: 378 378 Oil elevation arcs: units
Condensation pump:  yes  know Total refrigerant amount: g
Result
Visual check: Setup of outdoor part and indoor unit —— R good Q poor
Heat-exchanger, insulation, lines —— R good Q poor
Electrical fuse protection type............. A R good Q poor
Electrical power/control line Cu mm² / mm² / R good Q poor
Impermeability check: Vacuum mbar R good Q poor
Excess pressure mbar R good Q poor
Add. preparation: Refrigerant refill amount g R good Q poor
Shut-off valves open —— R good Q poor
Functional check: Condensation flow, condensation pump(s) —— R good Q poor
Cooling mode —— R good Q poor
Operational check: Compressor / fan mode —— R good Q poor
—— R good Q poor
Measurement tests: Room temperature / Air outlet temperature °C / °C / R good Q poor
Suction temperature / Overheating °C / K / R good Q poor
Comments:
Test of cold cycles
Operator / Setup location Name:
Street: Postal code, city:
Telephone: Fax:
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKS335H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKS335H in the language / languages: English as an attachment in your email.

The manual is 1,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKS335H

REMKO RKS335H User Manual - German - 28 pages

REMKO RKS335H User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info