587701
5
Zoom out
Zoom in
Previous page
1/28
Next page
The ML 261-681 air conditioning
equipment consists of an REMKO
ML...AT outdoor component and
an ML...IT interior unit.
The outdoor component serves to
output the heat extracted by the
interior unit from the room being
cooled.
In heating mode, the interior unit
dissipates the heat extracted by
the outdoor component.
The outdoor component can be
installed outdoors or indoors. The
latter requires the fulfilment of
certain conditions. The indoor unit
is designed for interior use and
should be mounted high up on a
wall. It is operated by an infrared
remote control.
The outdoor component comprises
a refrigerant and compressor,
liquefier with fins, liquefier
fan, reverse flow fan and flow
regulator. The outdoor component
is controlled by the regulator in the
indoor unit.
The indoor unit comprises a finned
vaporiser, vaporiser fan, controller
and condensation tray.
Winter controllers, floor and wall
brackets, refrigerant pipes and
condensation pumps are also
available as accessories.
Description of the
equipment
The equipment was shipped in
sturdy packaging. Immediately
check the equipment on delivery
and make a note of any damage or
missing parts on the delivery note.
Inform the forwarding agent and
contractual partner.
Warranty claims at a later date will
not be accepted.
Transportation and
packaging
Schematic of refrigerant circuit in indoor unit
Vaporiser fan
Connection to
suction pipe
Connection to injection pipe
Vaporiser
Refrigerant pipes are used to connect the indoor unit to the outdoor
component.
Outdoor
component
System layout
Injection pipe
Indoor unit
Indoor area
Outdoor area
Stop valve
Liquefier fan
Condensation pipe
Suction pipe
Condensation pipe
Control cable
Mains cable
M
M
Schematic of exterior refrigerant circuit
Liquefier fan
Connection valve
Suction pipe
Connection valve
Injection pipe
Compressor
Capillary tube flow regulatorFilter dryerLiquefier
Reverse flow valve
Connection for
pressure gauge
5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO ML 681 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO ML 681 in the language / languages: English as an attachment in your email.

The manual is 4,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO ML 681

REMKO ML 681 User Manual - German - 28 pages

REMKO ML 681 User Manual - Dutch - 28 pages

REMKO ML 681 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info