DESCRIPTION
The Digisight LRF N850/N870 riescope is designed for observation and
shooting in twilight or nighttime. In complete darkness (no stars or the Moon) use
of the built-in IR (or laser) Illuminator with 780nm wavelength (visible range) or
915nm wavelength (invisible range) is highly recommended. The riflescope is
equipped with a built-in multifunctional rangefinder with a working measuring
range of 400 metres. Your riflescope is a versatile device designed for a wide
range of professional and amateur applications such as hunting, sports
shooting, night video recording and observation.
GUIDELINES FOR OPERATION
The riescope has been designed for long-term use. To ensure long
performance, please adhere to the following:
Before use make sure that you have installed and fixed the mount according
to the instructions of the section “Installation of mount” (section 9 “Operation”).
Store with the lens cap on in the carrying case.
Switch off the scope after use.
The riflescope cannot be submerged in water.
Attempts to disassemble or repair the scope will void the warranty!
Clean the scope's optical surfaces only if necessary, and use caution. First,
remove (by blowing with a blower brush or canned air) any dust or sand particles.
Then proceed to clean by using camera/lens cleaning equipment approved for
use with multicoated lenses. Do not pour the solution directly onto the lens!
The riflescope can be used in various operating temperatures. However, if it
has been brought indoors from cold temperatures, do not turn it on for 3 to 4
hours. This will prevent external optical surfaces from fogging.
If the scope is unable to mount onto the rie securely, or you have doubts
about the mounting system, see a qualified gunsmith. Using the weapon with a
poorly mounted scope can lead to inaccurate target shooting!
To ensure reliable performance, it is recommended to carry out regular
technical inspections of the unit.
Do not leave batteries in the unit if it is not going to be used for an extended
period.
Batteries shall not be exposed to excessive heat such as sunshine, re or the like.
INSTALLATION OF BATTERIES
Unscrew and remove the battery cover from the battery compartment (15).
Install four AA batteries according to the marking on the battery compartment cap.
Replace and screw back the battery cover tightly.
Battery charge level is displayed on the status bar ( ).
In case of complete battery discharge, a red icon is flashing on the status
bar and in the centre of the display.
Note: to ensure long and reliable operation it is recommended that you use
quality rechargeable batteries with a capacity of at least 2500 mAh. Please do
not use batteries of different types or batteries with various charge levels.
EXTERNAL POWER SUPPLY
The riflescope can be powered with an external DC power supply (2.1mm pin)
with stabilized voltage ranging from V to 15V (max. consumption power 3W) or 9
a 12V vehicle socket.
External power supply (AC/DC) is to be connected to “Power (10) jack
located on the right side of the riflescope.
Note: central pin of the power supply that you connect to the power” jack of the
riflescope, must have marking “+”. The power supply may have marking .
Connection of an external power supply (icon on the status bar)
automatically cuts off power supply from batteries.
External power supply DOES NOT charge the batteries in the riflescope!
Attention! We suggest that you use battery packs EPS3 or EPS5 ensuring from
9 to 20 hours of continuous operation.
OPERATION
Installation of mount
Before using the riflescope you need to install the mount.
The riflescope can be used with various mount types such as Weaver, Euro-
prism, Los, MAK adapter etc. that allow the scope to be installed on different
types of rifles.
The mounting holes in the base of the riescope enable the mount to be
installed in one of the multiple positions. The choice of the mounting position
helps the user to ensure the correct eye relief depending on the rifle type.
Attach the mount to the base of the riescope using a hex-nut wrench and
screws (see installation scheme on page 5).
.Install the scope on the rifle and check if the position is suitable for you
If you are happy with its position, remove the scope, unscrew the screws
halfway, apply some thread sealant onto the thread of the screws and tighten
them fully (do not overtighten). Let the sealant dry for a while.
The riflescope is ready to be installed on a rifle and to be zeroed.
After first installation of your riflescope on a rifle, please follow instructions in
the section “Zeroing”.
Note: Please check that your riflescope is duly zeroed after changing a mount.
Starting the scope and image setup
Install the batteries according to the instructions in Section 7 “Installation of
batteries” or connect an external power supply.
Open the lens cap (2).
Turn on the riflescope turning the selector switch (3) to the “ON” position
within a couple of seconds the display will light up.
Adjust the sharpness of onscreen symbols with the eyepiece adjustment
ring (4). After this adjustment no further dioptre adjustment should be required,
regardless of distance or other factors.
To adjust the display brightness, rotate the controller (7). Brightness level
from 0 to 20 is shown next to the icon in the upper part of the display and then
on the status bar.
Press the controller (7) to switch to display contrast setup mode. Contrast
level from 0 to 20 is shown next to the icon in the upper part of the display and
then on the status bar.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pulsar Digisight LRF N870 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pulsar Digisight LRF N870 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 5,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info