566843
1
Zoom out
Zoom in
Previous page
1/2
Next page
HALOGEN HAND LAMP ELLIPS 500W
EN - 1
+ movement sensor
PLI-150 black
PLI-152 metal
We thank you for the purchase of this Profile product.
Note: It is important that you read this manual carefully
before using the product and be sure to save this manual
for possible use later.
Note
Check if building regulations apply to your area whereby
you must have the halogen hand lamp installed by an
accredited electrician. An electrician can give you
information about correct wiring. Never install the fitting
outside in rainy weather.
SWITCH OFF THE POWER BEFORE YOU INSTALL
THE HALOGEN HAND LAMP.
Correct installation
With installation outside preferably choose a place
under a roof.
Do not place the sensor head in direct or reflected
sunlight. The halogen hand lamp may then switch on
when not required. The sensor works best with
movement “crosswise” through the sensor's detection
field.
Connect the halogen hand lamp to a circuit with wall
switch.
Unscrew the stainless steel bolts on the side to take
the holder from the fitting.
Fix the holder to the wall with 2 screws. Do not fix the
holder to a highly flammable surface. Leave a distance
of at least 1 m between the halogen hand lamp and the
object to be illuminated. (see fig. 2) Install the halogen
hand lamp at least 2.5 m above the ground. (see fig.1)
Fig. 1 Fig. 2
Fix the halogen hand lamp back on the assembled
holder.
Remove the cover of the cable connection.
Pull the power supply wires through the opening with
the rubber packing.
Connect the electric wiring according to figures 3 and
4.
The halogen hand lamp must be connected to mains
voltage of 230V, max. fusing 16A.
Screw the cable connection cover tight again.
Fig. 3
Fig. 4
Always respect the instructions on the identification
label of the connected power cables.
Other uses than described above can cause damage
to the product and increase the risk of short-circuit,
fire, electric shocks, etc.
The product may not be adapted as a whole. The
safety instructions must be strictly observed.
Safety instructions
The importer accepts no responsibility for damage
claims with respect to objects or persons that result
from incorrect use or non-compliance with the safety
instructions. Any damage claims in such cases will
be declared null and void.
When replacing the halogen bulb the lamp must first
have cooled before the bulb is replaced. Also
disconnect the power supply. Do not exceed the
maximum wattage of 500W.
CAUTION: Never touch the bulb with your fingers.
Touching the bulb with your fingers can reduce the
life of the bulb.
Always replace cracked or broken glass by glass
with the same properties as the original glass.
Technical information
Working voltage: 230V AC (50/60 Hz)
Maximum lamp power: 500W.
Maximum current strength: 10/16A.
Dustproof and splash proof: IP44.
Passive infrared sensor (PIR).
Sensor angle: 120°.
Sensor range: 12 - 15 meters at with 25°C.
Lighting time: +/- 10 sec. – 10 min.
*
L = phase
*
= earthing
* N
= neutral wire
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Profile PLI-150 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Profile PLI-150 in the language / languages: English as an attachment in your email.

The manual is 0,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Profile PLI-150

Profile PLI-150 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info