Important ! Note!
Remove the mains plug before all maintenance work.
When the pump is often transported in the course of operation, it should be cleaned out
with clear water after every use.
All fibrous particles which may have built-up inside the pump housing should be removed
with a water jet.
Every 3 months the shaft ground and as should be cleaned from mud.
Remove deposits on the floater with clear water.
8.2 Cleaning the impeller
If excessive deposits collect in the pump case you must dismantle the bottom part of the pump
as follows:
1. Remove the intake cage from the pump case.
2. Clean the impeller with clear water.
Important! Do not put down or rest the pump on the impeller!
3. Re-assemble in reverse order
9 TECHNICAL DATA
type
POWXG9417
Voltage / frequency
230V~ 50Hz
Power input
750W
Delivery rate max..
13500 l/h
Delivery height max
7.5 m
Immersion depth max.
max. 7 m
Water temperature max.
35° C
Hose connection
5/4"
Foreign bodies up to
35 mm
Switching point high: ON
16, 20, 24 or, 28cm
Switching point high: OFF
ca. 5 cm
For clean/dirty water:
Dirty
Housing (plastic(P) / Stainless Steel (SS) )
SS
Water inlet (plastic / Stainless Steel (SS) )
SS
Weight
6.81kg
10 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a special
connecting cable which is available from our service department. Replacement of the
connecting cable should only be carried out by our service department (see last page) or
by a qualified specialist (qualified electrician).
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWXG9417 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWXG9417 in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWXG9417

Powerplus POWXG9417 User Manual - German - 8 pages

Powerplus POWXG9417 User Manual - Dutch - 8 pages

Powerplus POWXG9417 User Manual - French - 8 pages

Powerplus POWXG9417 Additional guide - All languages - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info