10 NOISE
11 Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
66 dB(A)
Acoustic power level LwA
94 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
12 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
CAUSE
REMEDY
Leakage of air from the
valve of the pressure
switch with the
compressor off.
Check valva that, due to wear
or dirt on the seal, does not
perform its function correctly.
Unscrew the hexagonal head of
the check valve, clean the valve
seat and the special rubber disk
(replace if worn). Reassemble
and tighten carefully (figures
14a-14b).
Reduction of
performance. Frequent
start-up. Low pressure
values.
Excessive performance
request, check for any leaks
from the couplings and/or
pipes. Intake filter may be
clogged.
Replace the seals of the fitting,
clean or replace the filter.
The compressor stops
and restarts
automatically after a
few minutes.
Tripping of the thermal cutout
due to overheating of the
motor.
Clean the air ducts in the
conveyor. Ventilate the work
area. Reset the thermal cutout.
On lubricated models, check oil
level and quality.
The compressor does
not stop and the safety
valve is tripped
Irregular functioning of the
compressor or breakage of
the pressure switch
Remove the plug and contact
the service center
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWX1760 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWX1760 in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWX1760

Powerplus POWX1760 User Manual - German - 11 pages

Powerplus POWX1760 User Manual - Dutch - 11 pages

Powerplus POWX1760 User Manual - French - 11 pages

Powerplus POWX1760 Additional guide - All languages - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info